PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS

NATURAL GAS

NOTE: An external regulator is required to reduce supply pressure to a maximum of 101/2" w.c. on Natural Gas systems operating at higher pressure.

MILLIVOLT PRESSURE

 

 

 

 

Regulator Pressure Setting:

3.5" w.c.

 

 

 

Pilot Regulator:

3.5" w.c.

 

 

 

Gas Inlet Pressure:

Max. 10 1/2" w. c.

Min. 5" w.c.

 

 

 

 

 

 

 

 

 

 

 

Gas Rate

 

 

 

 

 

 

Model Number

Type

Max. BTU/Hr

Min. BTU/Hr

 

 

 

 

 

 

CSVF20SNV(G-EBL-ES-EMB)

Milli-Volt

10,000

6,000

 

CSVF30SNV(G-EBL-ES-EMB)

Milli-Volt

32,000

20,000

 

 

 

 

 

 

PROPANE / LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.

MILLIVOLT PRESSURE

 

 

 

 

Regulator Pressure Setting:

10" w.c.

 

 

 

Gas Inlet Pressure:

Maximum 13" w.c.

 

 

 

 

 

Minimum 11" w.c.

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Rate

 

 

 

 

 

 

Model Number

Type

Max. BTU/Hr

Min. BTU/Hr

 

 

 

 

 

 

CSVF20SPV(G-EBL-ES-EMB)

Milli-Volt

10,000

6,000

 

CSVF30SPV(G-EBL-ES-EMB)

Milli-Volt

32,000

26,000

 

 

 

 

 

 

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches.

Milli-Volt control has four (4) positions:

OFF

-

All gas to the burner is shut off at the valve.

IGN

-

Valve position to light/maintain a standing pilot.

ON

-

Valve position to turn burners ON/OFF with remote switch/thermostat.

LOW/HI -

Variable position to control flame height (heat output). Both front and rear burners are in operation to

 

 

provide realistic glow and yellow flame.

PILOT/ODS

The gas log heater is fitted with a specially designed safety pilot (ODS assembly) light which senses the amount of oxygen available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can only be relit when adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a millivolt thermopile generator to provide power for remote activation.