Before you begin — This unit is supplied with six (6) ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove any traces of fibers.
| The positioning of the logs is critical to the safe and clean operation of | |
| this heater. Sooting and other problems may result if the logs are not | |
WARNING | properly and firmly positioned in the appliance. Never add additional | |
logs or embellishments such as pine cones, vermiculite or rock wool | ||
to the heater. Only use the logs and | ||
the unit. | ||
Failure to position the parts in accordance with diagrams below or | ||
| ||
| to use only parts specifically approved for this heater may result in | |
| property damage or personal injury. | |
|
| |
|
| |
CAUTION | DO NOT sprinkle volcanic rock on the logs or around the pilot or the | |
main burner. This may cause sooting. Only place volcanic rock on the | ||
floor of the fireplace. | ||
During initial operation of the new heater, burning logs will give off a | ||
paper burning smell and orange flames will be present. Simply open | ||
| the windows for a few hours to vent the odor. | |
|
|
DFX24C log placement
Figure 19 | Left Log | |
1. Install the rear log (#3) on back of burner. | ||
#2 |
2.Install the right log (#1) on burner pins on right side of burner.
3.Install the left log (#2) on burner pins on left side of burner.
Burner
Pins
Figure 19 -
DFX24C Log Placement
Right Log #1
Rear Log #3
Burner
Pins
LG699