SECURING HEATER TO FLOOR OR HEARTH

DFX & DBX Series Vent Free Fireplaces

FIREPLACE INSTALLATION

SECURING HEATER TO FLOOR OR HEARTH

Note: Clearance requirements as detailed in “Clearances and Height Requirements” section on Page 16 of this manual, must be met before securing the heater in place.

To prevent movement, the heater must be secured to the floor or hearth.

1.Open the control access door and remove the screen.

2.Remove carton containing the four-log set.

3.To remove the grate and base assembly, take out two (2) screws as shown in Figure 9.

4.Lift grate and base assembly out of the firebox.

5.Secure the firebox with two anchoring screws (3/16" x 1Z\v" length) supplied with the fireplace system. Figure 10

Note: If the unit is mounted on carpeting, tile or combustible material without the hearth, a metal or wooden base covering the entire width and depth of the base must be installed.