IMPORTANT SAFETY INFORMATION

Continued from page 3

16.Keep room area clear and free from combustible materi- als, gasoline and other flammable vapors and liquids.

17.Unvented gas heaters are a supplemental zone heater. They are not intended to be the primary heating appli- ance.

18.Unvented gas heaters emit moisture into the living area. In most homes of average construction, this does not pose a problem. In houses of extremely tight construction, additional mechanical ventilation is recommended.

19.During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.

The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use.

20.Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level. Refer to the National Fuel Gas Code.

21.The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

22.The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

23.Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

24.This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the fireplace.

25.Never burn solid fuels in a fireplace where a unvented room heater is installed.

26.Always have a fireplace screen in place when the appli- ance is in operation and, unless other provisions for combustion air are provided, the screen must have an opening(s) for induction of combustion air.

WARNING

 

Never connect unit to private

 

 

 

 

(non-utility) gas wells. This

 

 

gas is commonly known as

 

 

wellhead gas.

 

 

 

We suggest that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as Gas Specialists.

www.nficertified.org

4

59D1015

Page 4
Image 4
Monessen Hearth HVFL18 manual Never connect unit to private

HVFL18 specifications

The Monessen Hearth HVFL18 represents a notable innovation in the realm of vent-free fireplaces, designed with both aesthetics and functionality in mind. This unit is an excellent choice for homeowners looking for an efficient heating solution that combines style and convenience in one compact design.

One of the standout features of the HVFL18 is its impressive heat output. This fireplace boasts a maximum of 18,000 BTUs, making it powerful enough to warm various room sizes effectively. The vent-free design allows for maximum efficiency, ensuring that all the heat generated stays within the living space. Additionally, this model uses natural gas or propane, providing flexibility for installation based on the homeowner's preferences and existing connections.

The aesthetic appeal of the Monessen Hearth HVFL18 cannot be overlooked. It is designed with a realistic flame appearance that mimics the look of a traditional wood fire. The unit comes with a variety of decorative front options, allowing homeowners to customize the overall look to fit their interior design. Whether you're aiming for a contemporary or more classic style, the HVFL18 can complement your home beautifully.

A key technology integrated into the HVFL18 is its advanced burner system. The system is designed to produce taller, flickering flames, enhancing the ambiance of a cozy fire. Along with this, the unit incorporates a built-in oxygen depletion sensor, which automatically shuts off the fireplace if oxygen levels in the room fall below a safe threshold, ensuring peace of mind for users.

Ease of use is another significant characteristic of the HVFL18. The fireplace features an intuitive electronic ignition system, which simplifies the process of starting the unit and allows for quick adjustments to the flame height. Homeowners will appreciate how easily they can obtain instant warmth with just the press of a button.

Furthermore, the Monessen Hearth HVFL18 is designed for easy installation. With no need for venting, it can be added to a variety of spaces in homes where traditional fireplaces might be impractical. The compact size makes it suitable for smaller rooms, while still delivering robust heating performance.

In conclusion, the Monessen Hearth HVFL18 combines exceptional heating power, aesthetic versatility, and state-of-the-art technology, making it a top choice for those seeking a stylish and efficient fireplace solution. Its blend of safety features, user-friendly operation, and attractive design ensures that it will enhance any home while providing warmth and comfort during colder months.