Monessen Hearth Series, GRUF FOR USE OF OPTIONAL AK-4OUTSIDE AIR KIT, Combustion Air, Slab Floor

Models: GRUF Series GCUF Series GRUF Series

1 20
Download 20 pages 53.29 Kb
Page 16
Image 16
FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT

FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT

COMBUSTION AIR

1.Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any manner. Locate assembly a min. of 12" above the snow line to prevent blockage by snow accumulation.

2.Never mount the combustion air inlet assembly in a garage or storage area where combustible fumes such as gasoline might be drawn into the fireplace.

3.Combustion air can be drawn from the crawl space under a house when an adequate supply of air is provided by open ventilation.

4.CAUTION: Do not take combustion air from attic space or garage space.

5.Locate air supply inlet at least 3' away from any appliance vent terminal.

6.Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly. These conditions increase the resistance to the free flow of air through the duct. See Figures 16 through 19 for methods of installing the outside air for combustion assemblies.

Note: Fireplace model in illustrations may not be representative of your appliance.

Above

Snow

Level

Ground

Level

Basement

Wall

Inlet Grill in

8'max. Soffit

(Overhang)

 

Figure 17 - Concrete Slab Installation

Figure 16 - Basement Installation

(Optional Outside Air Runs)

Duct Extended

to Miss Joist

To Outside Wall

Inside Wall

Outside COMBUSTION AIR

Wall

Figure 18 - Installation Above Basement or

Figure 19 - 45° Corner Installation on

Crawl Space

Slab Floor

 

 

16

71D0530

Page 16
Image 16
Monessen Hearth Series FOR USE OF OPTIONAL AK-4OUTSIDE AIR KIT, Combustion Air, Concrete Slab Installation, Slab Floor