Monessen Hearth GRUF Clearances And Height Requirements, A - Mantel Clearances, Can Be, Less than

Models: GRUF Series GCUF Series GRUF Series

1 20
Download 20 pages 53.29 Kb
Page 9
Image 9
Figure 6A - Mantel Clearances

CLEARANCES AND HEIGHT REQUIREMENTS

4.Mantel clearances: The canopy supplied with the unit must be installed. If a combustible mantel is installed, it must meet the clearance requirements as shown in Figure 6a. However, if lower mantel height is desired, refer to page 14 and see Figure 6b.

Combustible material canFor Wide Profile Canopy contact top of fireplace.

 

 

12"

 

 

 

10"

 

 

 

8"

 

 

 

6"

23"

 

 

 

2

1

/2"

21"

 

19"

 

 

 

 

 

12"

16"

 

 

 

Non-combustible material only if needed to cover radiant top face

 

Figure 6B - Mantel Heights

Figure 6A - Mantel Clearances

For Wide Profile Canopy

5.Floor clearance: This inner chamber firebox floor must be installed at least 5" above any combustible flooring mate- rial, such as carpeting or asphalt tile, which is closer than 14" to the base of the firebox. See Figure 7.

Or

The inner chamber firebox floor may be installed nearer to the floor if a minimum of 14" of noncombustible material such as slate or marble is installed between the base of the firebox and the combustible flooring. See Figure 8.

 

Can Be

Non-Combustible

 

Less than 5"

Combustible

 

Material

Material

 

 

5" Minimum

14" Minimum

 

 

 

 

Figure 8 - Minimum Clearance above Combustible

Figure 7 - Minimum Clearance above

Flooring with Non-Combustible Material Installed at

Combustible Flooring

Base of Fireplace

71D0530