20 58D6002
PILOT
OFF
REMOTE CONTROL
CHECkING BURNER FLAME
In normal operation at full rate after 15 minutes, the following flame appearances should be observed:
Theleftandrightrearamesshouldbeyellowandextend1"-2"abovemiddlelogs.Theyellowamesshouldnot contact
thelogs.Thereshouldbeglowingembersonthefrontsurfaceofthemiddlelog.Note: The flames and embers will be
an opaque orange color during the burn off time.
Figure 19 - Correct Flame Appearance
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the stove. Do not place
ablowerinsidethe burnareaofthe stove.Ceilingfans maycreatedraftsthat alteramepatterns.Sooting andimproper
burningwillresult.
Duringmanufacturing,fabricatingandshipping,variouscomponentsofthisappliancearetreatedwithcertainoils,lmsor
bondingagents.Thesechemicalsarenotharmful,butmayproduceannoyingsmokeandsmellsastheyareburnedoffduring
theinitialoperationoftheappliance,possiblycausingheadachesoreyeorlungirritation.This is a normal and temporary
occurrence.
Theinitialbreak-inoperationshouldlasttwotothreehourswiththeburneratthehighestsetting.Providemaximumventila-
tionbyopeningwindowsordoorstoallowodorstodissipate.Anyodorsremainingafterthisinitialbreak-inwillbeslight
and will disappear with continued use.
Middle Log Middle Log