20 58D6002
PILOT
OFF
REMOTE CONTROL
FLAME APPEARANCE

CHECkING BURNER FLAME

In normal operation at full rate after 15 minutes, the following flame appearances should be observed:
Theleftandrightrearamesshouldbeyellowandextend1"-2"abovemiddlelogs.Theyellowamesshouldnot contact
thelogs.Thereshouldbeglowingembersonthefrontsurfaceofthemiddlelog.Note: The flames and embers will be
an opaque orange color during the burn off time.
Figure 19 - Correct Flame Appearance

OPERATING INSTRUCTIONS

Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the stove. Do not place
ablowerinsidethe burnareaofthe stove.Ceilingfans maycreatedraftsthat alteramepatterns.Sooting andimproper
burningwillresult.
Duringmanufacturing,fabricatingandshipping,variouscomponentsofthisappliancearetreatedwithcertainoils,lmsor
bondingagents.Thesechemicalsarenotharmful,butmayproduceannoyingsmokeandsmellsastheyareburnedoffduring
theinitialoperationoftheappliance,possiblycausingheadachesoreyeorlungirritation.This is a normal and temporary
occurrence.
Theinitialbreak-inoperationshouldlasttwotothreehourswiththeburneratthehighestsetting.Providemaximumventila-
tionbyopeningwindowsordoorstoallowodorstodissipate.Anyodorsremainingafterthisinitialbreak-inwillbeslight
and will disappear with continued use.
Middle Log Middle Log