Monster Cable HTS950 owner manual Troubleshooting, Symptom, Possible Cause, Remedy

Models: HTS950

1 68
Download 68 pages 40.03 Kb
Page 15
Image 15
TROUBLESHOOTING

TROUBLESHOOTING

Symptom

Possible Cause

Remedy

 

 

 

 

The PowerCenter is

The PowerCenter is not turned On.

Turn the PowerCenter switch on.

not receiving power.

 

Make sure the PowerCenter’s AC power plug is plugged into a properly grounded

 

 

 

 

 

120 volts (nominal) wall outlet.

 

 

In some households, a wall switch may need to be thrown to make the wall plug

 

 

 

active. Try turning on the light switches located near the wall unit.

 

 

 

 

 

Too many devices are connected, causing an overload,

Press the PowerCenter Thermal Circuit Breaker button in to reset. Please allow

 

tripping the Thermal Circuit Breaker.

 

10 minutes before attempting to reset. If you reset too soon, the breaker will

 

 

 

prematurely sense power overload and not allow unit to operate.

 

 

If the Circuit Breaker continues to trip, try moving one or more components

 

 

 

to another PowerCenter. You may be drawing too much current through

 

 

 

one PowerCenter.

 

 

 

 

Component is

The PowerCenter is plugged into a Switched outlet, but

Turn the component power On.

not receiving power.

power on the component is not On. In some instances, a

 

 

 

component plugged into a switched outlet won’t receive

 

 

 

power when the PowerCenter is turned On unless

 

 

 

the component power switch is also switched On.

 

 

 

 

 

 

Speakers emit

The PowerCenter is sharing AC power with equipment

Connect your PowerCenter to a dedicated outlet.

a humming or

that is not properly grounded.

Try unplugging different components from the PowerCenter one at a time to see if the noise

buzzing noise.

 

 

 

stops. If a component is discovered to be improperly grounded, attach a copper wire from

 

 

 

 

 

 

the component’s chassis to the nearest available grounding point.

 

 

 

 