Monte Carlo Fan Company 5AB52 House, 9Safety cable installation, Safety Cable Lag Screw

Models: 5AB52

1 4
Download 4 pages 21.14 Kb
Page 3
Image 3
House

7

Tighten both yoke set screws to further secure downrod.

10

Make wire connections to power source using wire nuts provided. Make sure that no filiments are outside of the wirenut. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

13

Raise the canopy up and align the two holes in the canopy with the two holes in the hanger bracket. Secure with two screws provided.

8

 

Carefully lift fan assembly onto mounting brack-

 

 

 

 

et. Rotate fan so that the notch on the ball

 

 

engages the ridge in the mounting bracket. This

 

 

will allow hands-free wiring.

 

 

 

 

 

 

11

 

House

 

 

Fan

Black

 

 

 

 

 

 

 

 

Black

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue

 

 

 

White

 

 

 

 

White

 

 

 

Green

 

 

Green(downrod)

 

 

 

 

 

Green(Bracket)

For pullchain controls, follow diagram above. Make sure that all exposed wiring is secured inside wire nuts. Note: Wires from house may vary in color and may not include ground wire. After wiring is conplete, gently push wires into junction box with wire nuts pointing upward. Refer to point 3 of safety tips.

14

Install blade arms using screws and washers provided. Tighten securely. Repeat for all 5 blades.

9Safety cable installation16

9Safety cable installation

Safety Cable

Lag Screw

safety cable

 

 

washer

 

 

 

3” lag

lock

 

 

 

screw

washer

 

 

 

For

Canadian

installation and for USA fan and

 

 

 

 

light

kit combinations over 35 lbs, in both flush

 

 

and downrod mode the safety cable must be

 

 

installed into the house structure beams using

 

 

the 3” lag screws,washers, and lock washers.

 

 

provided. Make sure that when the safety cable

 

 

is fully extended the leadwires are longer than

 

 

the cable and no stress is placed on the lead-

 

 

wires.

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Light Switch

Fan Switch

 

 

 

 

 

 

 

Wall

 

 

 

 

 

 

Control

 

For control of fan and optional light from wall location, follow diagram above. NOTE: A profes- sional electrician is recommended for this type of installation.

15

Check the motor for plastic shipping stabilizer tabs, and remove them if they are present. Attach blade assembly to motor using the motor screws and washers provided. Tighten screws securely.

After attaching blades install the switch housing using the three screws previously removed.

Page 3
Image 3
Monte Carlo Fan Company 5AB52 owner manual House, 9Safety cable installation, Safety Cable Lag Screw