Installation

SAFETY TIPS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE

FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

1.Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70- 1996), including fire-rated construction.

2.Use this unit only in the manner intended by the manufacurer. If you have any questions contact the manufacturer.

3.After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

4.Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

5.Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

6.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

8.WARNING – Risk of fire, electric shock, or personal injury, The fan in this box may be either directly supported from a structural framing mem- ber of a building and/or may be mounted to an outlet box marked acceptable for fan support of 31.8 kg. (70 lbs.) or less. Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

9.Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

10.Attach the mounting bracket using only the hardware supplied with the outlet box.

11.To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

12.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

13.NEVER place a switch where it can be reached from a tub or shower.

14.The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip- ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

15.Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

 

TOOLS REQUIRED

Phillips Screwdriver

Wire Cutters

Pliers

Step Ladder

1

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally.

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

4

Remove the 4 screws attaching the Mounting neck the mounting plate. Retain the 4 screws for re-assembly.

2OUTLET BOX METHOD

WARNING – Risk of fire, electric shock, or personal injury, The fan in this box may be either directly supported from a structural framing member of a building and/or may be mounted to an outlet box marked acceptable for fan support of 31.8 kg. (70 lbs.) or less. Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

5

BUILDING STRUCTURE METHOD

 

 

Mounting

Outlet box

 

Plate

 

 

 

 

 

 

 

 

Wood

Screws

Secure mounting plate directly to a joist from the buliding structure via the two knock out holes on the outlet box. Use only the appropri- ate wood screws and washers included with your fan. Caution: Wood screws must go through into the building joist.

3

Remove Safety bar from mounting bracket by loosing screws, sliding bar to side, and lifting it off the 2 screws.

6

FAN BRACE AND BOX METHOD

Install the mounting Plate to approved fan brace and box combination use only the hard- ware provided with the fan brace and box.

Page 2
Image 2
Monte Carlo Fan Company 5BGR56 Series owner manual Installation, Safety Tips

5BGR56 Series specifications

Monte Carlo Fan Company has gained recognition for its innovative ceiling fans, blending style and performance to transform spaces. One of the standout offerings from the brand is the 5BGR56 series, a product that encapsulates the essence of modern ceiling fans while incorporating classical elegance.

The 5BGR56 series is designed for versatility, making it an excellent choice for both residential and commercial settings. This model features a sleek design with a range of finishes, allowing it to seamlessly integrate with various interior decor styles. From contemporary to traditional, the fan adds a touch of sophistication while providing essential air circulation.

One of the main features of the 5BGR56 series is its powerful motor. The fan operates with a robust, energy-efficient motor that ensures optimal airflow while keeping energy consumption to a minimum. This efficiency is a key selling point for environmentally conscious consumers looking to reduce their carbon footprint without sacrificing comfort.

Additionally, the 5BGR56 series comes equipped with an integrated light kit option. This feature not only adds illumination to the room but also enhances the overall aesthetic of the fan. The light kit is designed to accommodate a range of bulb options, providing flexibility in brightness levels and energy efficiency, aligning with the company’s commitment to versatility.

Another notable characteristic of the 5BGR56 series is its whisper-quiet operation. The advanced engineering of the fan ensures that it runs silently, making it ideal for use in bedrooms, living rooms, or office spaces where noise could be a distraction. This silent performance is complemented by the fan's adjustable speed settings, allowing users to customize the airflow to their preference.

The Monte Carlo Fan Company also prioritizes installation ease, and the 5BGR56 series is no exception. The fan is designed for straightforward mounting and includes all necessary hardware, making it accessible for both professional installers and DIY enthusiasts.

In summary, the Monte Carlo Fan Company 5BGR56 series exemplifies contemporary design combined with advanced technology. With its robust motor, integrated light kit options, whisper-quiet operation, and user-friendly installation, this ceiling fan is a compelling choice for anyone seeking to enhance the comfort and style of their living or work space. Whether for home or business, the 5BGR56 series stands out as a hallmark of quality and innovation in ceiling fan engineering.