Align hole in downrod with hole in yoke and install cross pin. Install downrod into yoke. Install keeper into cross pin.

10Safety cable installation

Safety Cable

Lag Screw

safety cable

washer

3” lag lock screw washer

Fan and light kit combinations over 35 lbs, in both flush and downrod mode the safety cable must be installed into the house struc- ture beams using the 3” lag screws,washers, and lock washers. provided. Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires.

13

Raise fan with downrod assembled to the ceiling bracket and hang fan assembly. Be sure to rotate the downrod ball so that the notch in the bracket engages the slot in the ball.

16

Make wire connections to power source using wire nuts provided. Make sure that no filiments are outside of the wirenut. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

8

Tighten 2 downrod set screws and lock nuts.

11

Remove all 4 screws from Mounting bracket. These screws will not be needed for Downrod Mode installa- tion

14

Install remote receiver by sliding into opening in the Mounting bracket. Make sure that the dip switches on the Transmitter and the Receiver are set to the same position. See Fig 38 for remote operation

17

Next lift the cover ring and install knurled nuts as shown. Tighten the knurled nuts securely. The canopy should adjust for any irregularity in the ceiling or Outlet box.

9

Remote Transmitter Dip swtiches

Remote Receiver Dip switches

Set dip switches on the Remote Transmitter and Remote Receiver to the same settings. This must be done so the units will communcate properly. If you have other fans you can set to control from one transmitter by setting both receivers the same as the transmitter. If you have more than one fan with remote. You can set the dip switches to different positiosns to have seperate control.

12

Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the bracket.

15

white black

Make wiring connections as indicated above. White from fan to white from remote marked N. Blue from fan to blue from remote marked light. Black from fan to Black from remote marked L. White from house to white from remote marked AC N . Black from house to Black from remote marked AC L. Connect all green ground wires to Ground wire from House.

18

Flush Mount Installation

Pass leadwires and safety cable through the canopy.