•Leave the unit mounting means loose enough to allow for movement when performing the alignment procedure. They must be tightened after the alignment procedure is completed.
As with any such installed devices, the Canopy subscriber module and the Ethernet cable must be grounded in accordance with the latest revision of the National Electrical Code (NEC) and/or all country and local electrical codes to provide some protection against damage caused by
•Connect one end of an Ethernet cable to the Canopy subscriber module
•Connect other end of the Ethernet cable to the
•Connect one end of another Ethernet cable to the other
•Connect the other end of the Ethernet cable to the AC adapter.
The unused pins of the Ethernet cable (4,5,7 and 8) transmit power to the Canopy subscriber module. DO NOT place other networking equipment on the Ethernet cable between the AC adapter and the subscriber module. The module can be up to 328 feet
(100 meters) from the power supply.
•Plug the AC Adapter into an AC outlet.
•Plug the other side of the AC adapter’s Ethernet “pig tail” into the computer or network computer’s Ethernet port. DO NOT plug the Ethernet “pig tail” from the AC adapter into the subscriber module. See following wiring diagram.