Motorola SM02-UG-en S = P ⋅ G 4π d, Operating, Maximum, Effective, Modulation, Channel, Isotropic

Models: SM02-UG-en

1 34
Download 34 pages 21.98 Kb
Page 3
Image 3
Operating

Product Details for Products Tested for Compliance with Relevant EC Directives

(At this time, only the 5.7 GHz product has been tested for compliance with relevant EC directives.)

 

Operating

Maximum

Effective

Modulation

Channel

 

Frequency Range

Transmitter

Isotropic

Type

Spacing

 

 

Power

Radiated

 

 

 

 

 

Power (EIRP)

 

 

Access Point

5.725 to 5.825 GHz

200mW RMS

1 Watt EIRP

High Index

25 MHz

 

 

 

 

BFSK

20 MHz

 

 

 

 

 

 

Subscriber

5.725 to 5.825 GHz

200mW RMS

1 Watt EIRP

High Index

25 MHz

Module

 

 

 

BFSK

20 MHz

Subscriber

5.725 to 5.825 GHz

200mW RMS

63 Watts EIRP

High Index

25 MHz

Module with

 

 

 

BFSK

20 MHz

Reflector

 

 

 

 

 

Backhaul

5.725 to 5.825 GHz

200mW RMS

1 Watt EIRP

High Index

25 Mhz

 

 

 

 

BFSK

20 MHz

 

 

 

 

 

 

Backhaul

5.725 to 5.825 GHz

200mW RMS

63 Watts EIRP

High Index

25 MHz

with Reflector

 

 

 

BFSK

20 MHz

Exposure Note

The Canopy Subscriber Module (SM) must be installed to provide a separation distance of at least 20 cm (7.9 in) from all persons, when adding the Canopy reflector dish (in the 5.7 GHz band), the reflector dish must be installed to provide a separation distance of at least 1.5m (59.1 in) from all persons and does not emit a RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website http://www.hc-sc.gc.ca/rpb.

In both configurations the maximum RMS power does not exceed 200mW.

The applicable power density exposure limit is 10 Watt/m2, according to the FCC OET Bulletin 65, the ICNIRP guidelines, and the Health Canada Safety Code 6. The corresponding compliance distances referenced above have been determined by assuming worst-case scenarios. The peak power density (S) in the far-field of a radio-frequency source with rms transmit power P and antenna gain G at a distance d is

S = P G d 2

In the case of the Canopy SM without reflector, the gain is 8 dBi (a factor of 6.3), so the peak power density equals the exposure limit at a distance of 10 cm. A four-fold additional compliance margin is artificially introduced by doubling the distance to 20 cm.

In the case of the Canopy SM with reflector, the gain is 26 dBi (a factor of 400), so the peak power density equals the exposure limit at a distance of about 80 cm. An almost four-fold additional compliance margin is artificially introduced by defining the compliance distance of 1.5 m. The compliance distance is greatly overestimated in this case because the far-field equation neglects the physical dimension of the antenna, which is modeled as a point-source.

Software License Terms and Conditions

ONLY OPEN THE PACKAGE, OR USE THE SOFTWARE AND RELATED PRODUCT IF YOU ACCEPT THE TERMS OF THIS LICENSE. BY BREAKING THE SEAL ON THIS DISK KIT /

SM User Manual Issue 2

Page 3 of 34

Page 3
Image 3
Motorola SM02-UG-en S = P ⋅ G 4π d, Operating, Maximum, Effective, Modulation, Channel, Frequency Range, Transmitter, Type