HT750 and HT1250
Specifications
General Specifications
| Low Band | VHF | UHF | |
|
|
|
|
|
HT750 Channel Capacity |
|
| 4 or 16 |
|
|
|
|
|
|
HT1250 Channel Capacity |
|
| 128 |
|
|
|
| ||
Power Supply |
| Rechargeable battery 7.5V | ||
|
|
|
|
|
Dimensions: H x W x D |
|
|
|
|
With NiMH High Capacity Battery | 5.40 in x 2.26 in x 1.50 in (137mm x 57.5mm x 37.5 mm) | |||
With impres NiMH Battery | 5.40 in x 2.26 in x 1.60 in (137mm x 57.5mm x 40 mm) | |||
With impres NiMH FM Battery | 5.40 in x 2.26 in x 1.60 in (137mm x 57.5mm x 40 mm) | |||
With impres | 5.40 in x 2.26 in x 1.30 in (137mm x 57.5mm x 40 mm) | |||
Weight: |
|
|
|
|
With NiMH High Capacity Battery |
|
| 15.0 oz. (420g) |
|
With impres NiMH Battery |
|
| 17.5 oz. (488g) |
|
With impres NiMH FM Battery |
|
| 17.5 oz. (488g) |
|
With impres |
|
| 12.8 oz. (358g) |
|
Average Battery Life @ 5/5/90 Duty Cycle*: | Low | High | Low | High |
| Power | Power | Power | Power |
With NiMH High Capacity Battery | 11 hrs | 8 hrs | 11 hrs | 8 hrs |
With impres NiMH Battery | 17 hrs | 11 hrs | 17 hrs | 13 hrs |
With impres NiMH FM Battery | 16 hrs | 10 hrs | 16 hrs | 13 hrs |
With impres | 18 hrs | 11 hrs | 18 hrs | 14 hrs |
|
|
| ||
FCC description | AZ489FT3794 |
| ||
| AZ489FT4826 | |||
| AZ489FT1625 |
|
Transmitter
Specifications | Low Band | VHF | UHF | ||
|
|
|
| ||
Frequencies | |||||
|
|
| 450– 512 MHz | ||
Power Output | |||||
|
|
|
|
|
|
Frequency Stability | ±10 ppm |
| ±5 ppm @ 25 kHz |
| |
| ±2.5 ppm @ 12.5 kHz | ||||
Modulation Limiting | + 5.0 @ 20 kHz | ±2.5 @ 12.5 kHz/±4.0 @ 20 kHz/ | |||
|
|
| +5.0 @ 25 kHz |
| |
Spurs/Harmonics |
| - 36 dBm < 1 GHz |
|
| |
|
| - 30 dBm > 1 GHz |
|
| |
Channel Spacing | 20/25 kHz |
| 12.5/20/25 kHz |
| |
|
|
|
|
| |
FM Hum & Noise |
|
|
| ||
|
|
| |||
Adjacent Channel Power | - 60 dB @ 12.5, - 70 dB @ 25 kHz |
| |||
|
|
|
|
| |
Audio Response (300 – 3000 Hz) |
| +1 to - 3 dB |
|
| |
|
|
|
|
| |
Audio Distortion |
| 3% |
|
| |
|
|
|
|
|
|
FM Modulation | 25 kHz | 12.5 kHz | 25/30 kHz | 12.5 kHz | 25 kHz |
| 16KOF3E | 11KOF3E | 16KOF3E | 11KOF3E | 16KOF3E |
|
|
|
|
|
|
| Environmental Specifications | |
Operating Temperature |
| - 30 to +60° C |
|
|
|
Storage Temperature |
| - 55 to +85° C |
|
|
|
Humidity |
| 95% RH @ 8 Hr. |
|
|
|
ESD |
| IEC |
|
|
|
Water Intrusion |
| IP54 |
|
|
|
Receiver
Specifications | Low Band | VHF | UHF |
|
|
|
|
Frequencies | 29.7– 42 MHz | 403– 470 MHz | |
| 35– 50 MHz |
| 450– 512 MHz |
Hum and Noise | |||
|
|
| |
Sensitivity (12 dB SINAD) EIA | .30 µV | .25 µV | |
Sensitivity (20 dB SINAD) ETS |
| .50 µV |
|
|
|
| |
HT750 Channel Spacing | 20/25 kHz | 12.5/20/25 kHz | |
|
|
| |
HT1250 Channel Spacing | 20/25 kHz | 12.5/15/20/25/30 kHz | |
|
| PLL Steps 2.5, 3.125 kHz | |
Intermodulation |
| 70 dB |
|
Adjacent Channel Selectivity | 60 dB @ 12.5 kHz/70 dB @ 25 kHz | ||
|
|
|
|
Spurious Rejection |
| 70 dB |
|
|
|
|
|
Rated Audio |
| 0.5 W |
|
Audio Distortion @ Rated Audio |
| 3% typical |
|
|
|
|
|
Audio Response (300 – 3000 Hz) |
| +1 to |
|
|
|
|
|
Conducted Spurious Emission |
|
| |
FCC Part 15 |
|
|
Portable Military Standards 810 C, D, & E
Applicable | 810C | 810D | 810E |
| |||
|
|
|
|
|
|
|
|
| Methods | Procedures | Methods | Procedures | Methods | Procedures |
|
|
|
|
|
|
|
|
|
Low Pressure | 500.1 | 1 | 500.2 | 2 | 500.3 | 2 |
|
|
|
|
|
|
|
|
|
High Temperature | 501.1 | 1,2 | 501.2 | 1,2 | 501.3 | 1,2 |
|
|
|
|
|
|
|
|
|
Low Temperature | 502.1 | 2 | 502.2 | 1,2 | 502.3 | 1,2 |
|
|
|
|
|
|
|
|
|
Temperature Shock | 503.1 | 1 | 503.2 | 1 | 503.3 | 1 |
|
|
|
|
|
|
|
|
|
Solar Radiation | 505.1 | 1 | 505.2 | 1 | 505.3 | 1 |
|
|
|
|
|
|
|
|
|
Rain | 506.1 | 1,2 | 506.2 | 1,2 | 506.3 | 1,2 |
|
|
|
|
|
|
|
|
|
Humidity | 507.1 | 2 | 507.2 | 2,3 | 507.3 | 2,3 |
|
|
|
|
|
|
|
|
|
Salt Fog | 509.1 | 1 | 509.2 | 1 | 509.3 | 1 |
|
|
|
|
|
|
|
|
|
Dust | 510.1 | 1 | 510.2 | 1 | 510.3 | 1 |
|
|
|
|
|
|
|
|
|
Vibration | 514.2 | 8,10 | 514.3 | 1 | 514.4 | 1 |
|
|
|
|
|
|
|
|
|
Shock | 516.2 | 1,2,5 | 516.3 | 1,4 | 516.4 | 1,4 |
|
|
|
|
|
|
|
|
|
Factory Mutual Approvals
The HT Series is Factory Mutual approved and Canadian Standard Association approved as intrinsically safe for use in Classes I, II, and III, Division 1, Groups C, D, E, F and G, as well as