Image 2

WARNING:

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX- IDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.

WARNING:

NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNING:

FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UN- KNOWN CHEMICALS.

WARNING:

The State of California requires the following warning:

COMBUSTION BY-PRODUCTS PRODUCED WHEN US- ING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).

CONTENTS

HEATER SPECIFICATIONS

E-2

WARNINGS

E-2

OPERATING PRECAUTIONS

E-3

SAFETY PRECAUTIONS

E-3

ODOR FADE WARNING

E-4

PREPARING FOR OPERATION

E-5

BATTERY CHARGING PROCEDURE

E-5

BATTERY INFORMATION

E-5

BATTERY RECYCLING INFORMATION

E-5

HEATER OPERATION

E-6

MAINTENANCE AND STORAGE

E-6

SERVICING

E-6

WIRING SCHEMATIC

E-7

PARTS LIST

E-8

SIZE AND CAPACITY OF PROPANE INFORMATION

E-9

WARRANTY INFORMATION

E-10

SPECIFICATIONS

Type of Gas:

For use with Propane Only

Gas Supply Pressure

 

 

to regulator

Max:

200 psi (1380 kPa)

 

Min:

5 psi (34.4 kPa)

regulator out

38" WC (9.47 kPa)

Manifold Pressure:

36" WC (8.97 kPa)

Electrical Input:

110/220V, 50/60 Hz, 1Ø, 2a

Ignition:

Manual, piezo igntion

Primary Flame Control:

Thermocouple Operated Gas Valve

High Temperature Control:

240°F (115°C)

 

Min. Ambient Temp. Rating 0°F (-17.8°C)

Model:

MH35CLP

Rating:

35,000 BTU/hr

 

(10.25 kW)

Fuel Consumption:

1.6 #/hr (.72 kg/hr)

Fuel Orifice Port Size:

.1.40mm

Fan Rating:

117 cfm

Forced Air Propane Construction Heater