Mr. Heater MH15 Odor Fade Warning, General Information, 2.4WARNING, Asphyxiation Hazard

Models: MH15

1 16
Download 16 pages 54.73 Kb
Page 3
Image 3
2.4WARNING

Model

 

Face Guard

 

 

 

 

MH15

 

 

 

 

Valve/ ODOR FADE WARNING Regulator Mr. Heater #73420

1 Lb. (Nominal) cylinder shown is not supplied w/heater

Figure 1

Plastic

Stand (Base)

Figure 2

2.3Check to assure that bottom of cylinder is in contact with base plastic lugs. – Fig. 2.

2.4WARNING

Never touch heater while in operation to avoid injury. Move heater by grasping the propane cylinder carefully.

2.5Read all instructions before lighting heater.

 Asphyxiation HazardWARNING

STOP-LOOK-READ-UNDERSTAND these warning instructions to avoid serious injury, fire, asphyxiation, death or other life threatening conditions.

GENERAL INFORMATIONWARNING

DO NOT LEAVE HEATER UNATTENDED OR IN OPERATION WHILE SLEEPING

ODOR FADE WARNING

WARNING

Manual background Asphyxiation Hazard

Do not use this heater for heating human living quarters.

Do not use in unventilated areas.

The flow of combustion and ventilation air must not be obstructed.

Proper ventilation air must be provided to support the combustion air requirements or the heater being used.

Refer to the specification section of the heater’s manual, heater dataplate, or contact the factory to determine combustion air ventilation requirements of the heater.

Lack of proper ventilation air will lead to improper combustion.

Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death.

Symptoms of carbon monoxide poisoning can include headache, dizziness and difficulty in breathing.

GENERAL INFORMATION

A.The MH15 is a high pressure propane appliance and is designed to be operated from a 14.1 or 16.4 ounce disposable propane cylinder. (Propane cylinder not included.) Every unit is tested during manufacturing and shipped fully assembled except for the plastic stand.

B.These heaters are equipped with automatic Safety Shutoff Valves. The gas flow will automatically stop if the heater fails to operate for any reason.

C.Maximum safety and convenience have been built into the Hi-Med-Lo Control Valve/Regulator. The following table lists the approximate BTU’s consumed and the operating hours you can reasonably expect from disposable propane cylinders.

Valve

 

 

 

Position

BTU Input

Cylinder 14.1 oz.

Cylinder 16.4 oz.

Hi

15,000

1.3 hours

1.5 hours

Med

12,000

1.6 hours

1.8 hours

Lo

10,000

1.9 hours

2.2 hours

Figure 3

 

 

 

E3

Page 3
Image 3
Mr. Heater MH15 operating instructions Odor Fade Warning, General Information, 2.4WARNING, Asphyxiation Hazard