MAINTENANCE AND REPAIR INSTRUCTIONS
The cams are lubricated with a sufficient amount of high- temperature grease. To keep the attachment operating efficiently, apply a
Yokes
Cams
Fig. 7
WARNING: Failure to apply
NOTE: We recommend that you take the hedge trimmer attachment to your nearest authorized service dealer to replace the blade.
NOTE: Disconnect the hedge trimmer attachment from the powerhead before replacing the blade.
REMOVING BLADEWARNING: Blades are sharp. When handling blade assembly, do not place your hand or fingers between blades or in any position where they could get pinched or cut.
1.Place hedge trimmer upside down on workbench and remove two (2) bottom plate screws (Fig. 8).
2.Remove bottom plate.
Bottom Plate Screw
Bottom Plate
Fig. 8
3.Align the cams (Fig. 9).
4.Remove the four (4) blade screws (Fig. 9).
Blade ScrewsCamsFig. 9
5.Push the red end of the blade bar towards the cams. This will loosen the blade plate so that it can be removed easily from the cams (Fig. 10).
Fig. 10
6.Remove the blade by lifting and rotating it so that the blade yokes clears the lower cam first (Fig. 11).
45° ROTATE
Fig. 11
9