CABLE INSTALLATION
Control Box Removal
1.Using a 7/16 socket remove the mounting bolts (3) that secure the control box to the support bracket.
2.Once the bolts have been removed, fl ip the panel downward to gain access to the connection points.
Data Cable Connections
1.Wire data cable into control box as shown in Figure 2.
2.Crimp a
3.Crimp a
4.Crimp a
5.Crimp a
6.Crimp a
7.Splice the WHITE wire labeled EMERGENCY STOP with the RED or PINK wire from the engine oil sensor.
8.Insert connector end of data cable into Miratron receiver.
Remote Control Cable Connections
1.Connect the remote control cable to the control box as shown in Figure 2 .
2.Splice the WHITE wire labeled REMOTE (data cable) with the BLACK wire from the yellow remote cable
3.Crimp a
4.
5.Insert the yellow remote control cable into the
6.Reconnect negative battery cable to battery.
INSTALLATION/OPERATION MANUAL — REV. #0 (08/19/09) — PAGE 9