INSTALLATION

OUTDOOR INSTALLATION

Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes.

The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture. Failure to do will result in deterioration of the insulation and will result in short circuits and grounding.

Foreign materials such as dust, sand, lint and abrasive materials have a tendency to cause excessive wear to engine and alternator parts.

CAUTION

Pay close attention to ventilation when operating the generator inside tunnels and caves.The engine exhaust contains noxious elements. Engine exhaust must be routed to a ventilated area.

INDOOR INSTALLATION

Exhaust gases from diesel engines are extremely poisonous. Whenever an engine is installed indoors the exhaust fumes must be vented to the outside. The engine should be installed at least two feet from any outside wall. Using an exhaust pipe which is too long or too small can cause excessive back pressure which will cause the engine to heat excessively and possibly burn the valves.

MOUNTING

The generator must be mounted on a solid foundation (such as concrete) and set fi rmly on the foundation to isolate vibration of the generator when it is running.The generator must set at least 6 inches above the fl oor or grade level (in accordance to NFPA 110, Chapter 5-4.1). DO NOT remove the metal skids on the bottom of the generator. They are to resist damage to the bottom of the generator and to maintain alignment.

GENERATOR GROUNDING

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifi es that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

NEC articles 250-64(b) and 250-66 set the following grounding requirements:

1.Use one of the following wire types to connect the generator to earth ground.

a.Copper - 10 AWG (5.3 mm2) or larger.

b.Aluminum - 8 AWG (8.4 mm2) or larger.

2.When grounding the generator (Figure 2) connect the ground cable between the lock washer and the nut on the generator and tighten the nut fully. Connect the other end of the ground cable to earth ground.

3.NEC article 250-52(c) specifies that the earth ground rod should be buried a minimum of 8 ft. into the ground.

NOTICE

When connecting the generator to any buildings electrical system ALWAYS consult with a licensed electrician.

DCA45SSIU3 50 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (12/19/08) — PAGE 15

Page 15
Image 15
Multiquip CDA45SSIU3 manual Outdoor Installation, Indoor Installation, Mounting, Generator Grounding

CDA45SSIU3 specifications

The Multiquip CDA45SSIU3 is a versatile and powerful piece of equipment primarily designed for the construction and industrial sectors. As part of Multiquip's range of durable and reliable construction machinery, the CDA45SSIU3 is engineered to meet the demands of various tasks, including compacting soil, asphalt, and granular materials.

One of the standout features of the CDA45SSIU3 is its robust, high-performance engine. Powered by a reliable and efficient fuel system, the machine ensures optimal performance even under the heaviest loads. This not only improves productivity but also reduces fuel consumption, resulting in significant cost savings for contractors and operators.

The CDA45SSIU3 is equipped with advanced vibration technology, which provides exceptional compaction capabilities. Its dual-pump system delivers consistent performance, enabling operators to achieve the desired density in various soil types. This feature enhances the efficiency of the compaction process, making it ideal for preparing foundations, roadways, and other critical infrastructure.

Another notable characteristic of the CDA45SSIU3 is its user-friendly design. The machine comes with an intuitive control panel that allows operators to easily manage its functions. This ease of use reduces the learning curve for new operators, allowing them to quickly become proficient and maximizing productivity on job sites.

Durability is a key consideration in the design of the CDA45SSIU3. Constructed with high-quality materials, it withstands the rigors of demanding environments. The heavy-duty frame and components ensure longevity and consistent performance over time while minimizing maintenance requirements.

Additionally, the CDA45SSIU3 is designed with mobility in mind. Its compact dimensions and lightweight structure make it easy to transport between job sites. This portability ensures that operators can efficiently transition from one project to another without unnecessary delays.

Safety features are also a priority with the CDA45SSIU3. Equipped with safeguards that prevent accidental operation and enhance operator safety, the machine provides peace of mind while in use.

In summary, the Multiquip CDA45SSIU3 stands out as a powerful, reliable, and efficient solution for compaction tasks in construction and industrial applications. Its advanced engine, vibration technology, user-friendly controls, durable construction, and safety features make it an excellent choice for professionals seeking high-performance equipment. With the CDA45SSIU3, users can expect enhanced productivity, reduced operating costs, and reliable performance in various conditions.