ENGINE OPERATING PANEL

1

2

3

4

5

6

7

8

9

 

 

 

 

WATER TEMP.

OIL PRESS.

FUEL LEVEL

 

 

 

 

 

 

AIR FILTER

COOLANT LEVEL

 

 

 

ON

OFF

Figure 5. Engine Operating Panel

The defi nitions below describe the controls and functions of the DCA300SSC Engine Operating Panel (Figure 5).

1.Tachometer — Indicates engine speed in RPM’s for 60 Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.

2.Oil Pressure Gauge — During normal operation this gauge be should read between 28 to 85 psi. (193~586 kPa). When starting the generator the oil pressure may read a little higher, but after the engine warms up the oil pressure should return to the correct pressure range.

3.WaterTemperature Gauge — During normal operation this gauge be should read between 167° and 203°F (75°~95°C).

4.Charging Ammeter Gauge — Indicates the current being supplied by the engine’s alternator which provides current for generator’s control circuits and battery charging system.

5.Fuel Gauge — Indicates amount of diesel fuel available.

6.Engine Warning Lamps — There are three engine warning lamps, they are defi ned as follows:

a.Overheat Lamp — This lamp goes ON when the cooling water temperature rises abnormally. If the lamp goes ON during normal operation of the generator, the emergency shutdown device will stop the engine automatically.

b.Low Oil Pressure Lamp — During normal operation of the generator this lamp should remain OFF. When the Auto-OFF/Reset-Manual switch is set

to the MANUAL position to start the engine, the lamp will be lit. When the oil pressure rises after start-up the lamp will go OFF. If this lamp is ever lit (ON) during normal operation of the generator, the emergency shutdown device will stop the engine automatically.

c.Low Fuel Level Lamp — When this lamp is ON, it is time to stop the engine and add fuel. Remember to let the engine cool before adding fuel.

d.Air Filter Alarm — When the air fi lter

element is clogged, this lamp goes ON indicating the element should be immediately cleaned or replaced.

e.Coolant Level Alarm — This lamp

goes ON when the coolant level is low. If this lamp goes ON while the engine is in operation, the emergency shutdown device will automatically stop the engine.

7.Engine Speed Switch — This switch controls the speed of the engine (low/high).

8.Pre-Heat Lamp — When ECU is placed in AUX position, pre-heat lamp will be ON. When pre-heat cycle is completed, lamp will turn OFF.

9.Emergency Stop Button — Push this button inward to stop the engine in the event of an emergency. DO NOT use this button as a means of stopping the engine.

10.Battery Switch — This switch should be set to the ON position during normal operation.When the engine has been stop, place this switch in the OFF position. DO NOT turn this switch during normal operation, it could cause damage to the electrical equipment.

PAGE 20 — DCA300SSC GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (06/25/09)

Page 20
Image 20
Multiquip DCA300SSC manual Engine Operating Panel, Air Filter Alarm When the air fi lter

DCA300SSC specifications

The Multiquip DCA300SSC is a durable and powerful skid-mounted diesel generator designed for a range of applications, including construction sites, events, and emergency backup power. With a robust operational capacity of 300 kilowatts, this generator stands out for its reliability and efficiency in providing continuous power.

One of the key features of the DCA300SSC is its commercial-grade engine. The generator is equipped with a reliable and efficient diesel engine that ensures optimal performance under various operating conditions. This engine is designed for durability and longevity, minimizing the need for frequent maintenance. The generator's high fuel efficiency reduces operational costs, making it an economical choice for businesses and contractors.

Another notable characteristic of the DCA300SSC is its advanced sound attenuation technology. This design feature significantly lowers noise levels during operation, which is essential for applications in populated areas or sensitive environments. The generator is housed in a weather-resistant enclosure that protects it from environmental factors, ensuring consistent performance regardless of weather conditions.

In terms of power management, the DCA300SSC is equipped with a sophisticated digital control panel that allows users to monitor and manage the generator’s performance effectively. The control panel displays vital information, such as voltage, frequency, and run-time hours, facilitating easy operation and troubleshooting. This technology also integrates automatic voltage regulation, enhancing the generator's stability and safety during operation.

Safety is a priority in the design of the DCA300SSC. It is built with multiple safety features, including low oil pressure shutdown, high coolant temperature shutdown, and over-speed protection. These measures provide peace of mind to users by reducing the risk of equipment failure and ensuring safe operation.

The compact design and skid-mounted configuration of the DCA300SSC allow for easy transport and installation, making it a versatile solution for a variety of industries. Additionally, the generator can be configured for different voltage outputs, further increasing its adaptability for specific applications.

In summary, the Multiquip DCA300SSC is a powerful and versatile generator known for its reliability, efficiency, and advanced features. With its durable construction, advanced sound attenuation, user-friendly control panel, and robust safety features, it meets the demands of both commercial and industrial applications with ease. Whether for temporary power supply or backup generation, the DCA300SSC is a suitable choice for professionals seeking dependable energy solutions.