Multiquip DCA400 manual Install Newtrailer return port fittings, Trailer, Drain, Return, Port

Models: DCA400

1 6
Download 6 pages 55.02 Kb
Page 3
Image 3
Install Newtrailer return port fittings

4. Disconnect drain hose from trailer return port. See

Figure 6.

Install Newtrailer return port fittings

Trailer

Drain

Return

 

Port

 

Disconnect

Drain Hose

Figure 6. Disconnect Drain Hose

Refer to Figure 8.

3

4

2

Drain

Existing 90º Hose

Fitting

5.Remove fittings from trailer return port. Retain the 90º fitting, and discard the others. See Figure 7.

RetainTrailer 90º Fitting

Remove DrainReturnPort

Fittings

Trailer

Return Port

Figure 7. Remove Trailer Return Port Fittings

Figure 8. New Trailer Return Port Fittings

Disconnect NOTICE

Apply pipe sealant to all fittings.

1.Install Item 3, tee fitting, into trailer return port.

2.Install Item 2, straight fitting, into the right side of the tee fitting.

3.Install existing 90º fitting into Item 2. Connect to drain hose.

4.Install Item 4, straight fitting, into the left side of the tee.

DCA400 Series — Fuel Return line kit instructions p/n 35499 — Rev. #0 (01/26/11) — Page 3