4. Disconnect drain hose from trailer return port. See |
Figure 6. |
Install Newtrailer return port fittings
Trailer | Drain |
Return |
|
Port |
|
Disconnect
Drain Hose
Figure 6. Disconnect Drain Hose
Refer to Figure 8.
3
4 |
2
Drain
Existing 90º Hose
Fitting
5.Remove fittings from trailer return port. Retain the 90º fitting, and discard the others. See Figure 7.
Retain 90º Fitting
Remove
Fittings
Trailer
Return Port
Figure 7. Remove Trailer Return Port Fittings
Figure 8. New Trailer Return Port Fittings
NOTICE
Apply pipe sealant to all fittings.
1.Install Item 3, tee fitting, into trailer return port.
2.Install Item 2, straight fitting, into the right side of the tee fitting.
3.Install existing 90º fitting into Item 2. Connect to drain hose.
4.Install Item 4, straight fitting, into the left side of the tee.
DCA400 Series — Fuel Return line kit instructions p/n 35499 — Rev. #0 (01/26/11) — Page 3