Multiquip DCA400 Install New Return extension hose, Install new vent hose, Engine Return Hose

Models: DCA400

1 6
Download 6 pages 55.02 Kb
Page 4
Image 4
Install New Return extension hose

Install New Return extension hose

Refer to Figure 9.

1.Connect Item 6, return extension hose, to item 4. Secure with clamp, Item 5.

2.Install Item 7, straight fitting, between extension hose and existing engine return hose. Secure with clamps.

Engine

Return Hose

5

7 Engine 5

Figure 9. New Return Extension Hose6

5 9Figure 10. Spiral TubingInstall new vent hoseReturnPortPick-UpFigure 11. Vent HoseManual backgroundManual backgroundManual backgroundManual background 4Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Figure 9. New Return Extension Hose

3.Install spiral tubing, Item 10, around return extension hose. Secure with cable ties, Item 9. See Figure 10.

9

10

9

Figure 10. Spiral Tubing

Install new vent hose

1.Connect Item 8, vent hose, to generator pick-up port and return port. Secure with clamps, Item 5. See Figure 11.

8

5

 

5

Return

 

 

Port

 

 

Pick-Up

 

 

Port

 

 

Figure 11. Vent Hose

DCA400 Series — Fuel Return line kit instructions p/n 35499 — Rev. #0 (01/26/11) — Page 4

Page 4
Image 4
Multiquip DCA400 manual Install New Return extension hose, Install new vent hose, Engine Return Hose, Port, Spiral Tubing