Safety Information

FUel SaFetY

DANGER

„DO NOT start the engine near spilled fuel or combustible fl uids. Diesel fuel is extremely fl ammable and its vapors can cause an explosion if ignited.

„alWaYS refuel in a well-ventilated area, away from sparks and open fl ames.

„alWaYS use extreme caution when working with flammable liquids.

„DO NOT fi ll the fuel tank while the engine is running or hot.

„DO NOT overfi ll tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

„Store fuel in appropriate containers, in well-ventilated areas and away from sparks and fl ames.

„never use fuel as a cleaning agent.

„DO NOT smoke around or near the equipment. Fire or explosion could result

from fuel vapors or if fuel is spilled on a hot engine.

TOWING SAFETy

CAUTION

„Check with your local county or state safety towing regulations, in addition to meeting

Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

„Refer to MQ Power trailer manual for additional safety information.

„In order to reduce the possibility of an accident while transporting the generator on public roads, alWaYS make sure the trailer that supports the generator and the towing vehicle are mechanically sound and in good operating condition.

„alWaYS shutdown engine before transporting

„Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross vehicle weight rating.”

„alWaYS inspect the hitch and coupling for wear. never tow a trailer with defective hitches, couplings, chains, etc.

„Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

„alWaYS make sure the trailer is equipped with a safety chain.

„alWaYS properly attach trailer’s safety chains to towing vehicle.

„alWaYS make sure the vehicle and trailer directional, backup, brake and trailer lights are connected and working properly.

„DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

„The maximum speed for highway towing is 55 mph unless posted otherwise. Recommended off-road towing is not to exceed 15 mph or less depending on type of terrain.

„Avoid sudden stops and starts.This can cause skidding, or jack-knifi ng. Smooth, gradual starts and stops will improve towing.

„Avoid sharp turns to prevent rolling.

„Trailer should be adjusted to a level position at all times when towing.

„Raise and lock trailer wheel stand in up position when towing.

„Place chock blocks underneath wheel to prevent rolling while parked.

„Place support blocks underneath the trailer’s bumper to prevent tipping while parked.

„Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

DCA45SSIU4 60 hz Generator • operation and parts manual — rev. #1 (10/24/13) — page 9

Page 9
Image 9
Multiquip dca45ssiu4 manual FUel SaFetY, Towing SAFETy, „ never use fuel as a cleaning agent

dca45ssiu4 specifications

The Multiquip DCA45SSIU4 is a robust and versatile diesel generator designed to meet the demands of various applications, ranging from construction sites to emergency power backup. With a powerful engine and a comprehensive array of features, this generator is engineered to deliver reliable performance and fuel efficiency.

At the heart of the DCA45SSIU4 is its 45 kVA output capability, which is powered by a highly efficient Yanmar engine. This engine not only provides ample power but also features advanced emissions technology that meets stringent environmental regulations. Users can rely on the DCA45SSIU4 for consistent energy delivery while minimizing their carbon footprint, making it a great choice for eco-conscious projects.

One of the standout features of the DCA45SSIU4 is its compact design. The generator is housed within a durable weatherproof enclosure that ensures reliable operation in various conditions. The enclosure is sound attenuated, significantly reducing noise levels, which is critical for projects in urban or noise-sensitive areas. This design allows the generator to operate quietly without disturbing the surrounding environment.

The DCA45SSIU4 is equipped with state-of-the-art digital control technology, featuring an intuitive user interface that simplifies monitoring and operation. This control panel includes essential indicators for voltage, frequency, and running hours, enabling users to track performance and maintenance needs efficiently. The generator also has a built-in automatic start/stop function, which activates the unit when power is needed and turns it off when it is not, thus enhancing convenience and saving fuel.

Another notable characteristic is its versatility in fuel efficiency. The DCA45SSIU4 can operate for extended periods on a single tank of diesel, making it ideal for both short-term and long-term power needs. Additionally, its features include a robust frame with forklift pockets and lifting points, ensuring easy transportation and setup at job sites.

In conclusion, the Multiquip DCA45SSIU4 combines power, durability, and advanced technology, positioning itself as an excellent solution for anyone in need of reliable temporary or backup power. Its features, including a powerful Yanmar engine, compact design, digital control technology, and exceptional fuel efficiency, make it a top choice for professionals across various industries. Whether for construction, events, or emergency situations, the DCA45SSIU4 stands out as a dependable generator that meets modern demands.