Multiquip DCA70US13CAN manual Specifications, Model, Maximum Lifting Capacity, Armature Connection

Models: DCA70US13CAN

1 86
Download 86 pages 10.65 Kb
Page 12
Image 12
Specifications

 

 

 

 

 

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1. Generator Specifications

 

 

 

Model

DCA-70USI3CAN

 

 

Type

Revolving field, self ventilated,

 

 

open protected type synchronous generator

 

 

 

 

 

Armature Connection

Star with Neutral

 

Zigzag

 

 

Phase

3

 

 

Single

 

 

Standby Output

77 kVA (62 kW)

 

44 KW

 

 

Prime Output

70 kVA (56 KW)

 

40 KW

 

 

Voltage

240 or 480V

 

240 or 120V

 

 

 

 

 

 

 

 

Frequency

60 Hz

 

 

Speed

1800 rpm

 

 

Power Factor

0.8

 

 

1.0

 

 

Aux. AC Power

Single Phase, 60 Hz

 

 

Voltage

120V

 

 

 

Output

4.8 Kw (2.4 kW x 2)

 

 

Weight (No Fuel)

3,771 lbs. (1,710 kg)

 

 

Weight (Fuel)

4,553 lbs. (2,065 kg)

 

 

Maximum Lifting Capacity

14,050 lbs. (6,370 kg)

 

 

 

Table 2. Engine Specifications

 

 

 

Model

ISUZU BJ-4JJ1XYGD-02 Tier 3

 

 

Type

4 cycle, water-cooled, direct injection, turbo-charged

 

 

air to air intercooled

 

 

 

 

 

No. of Cylinders

4 cylinders

 

 

Bore x Stroke

3.76 in. x 4.13 in. (95.4 mm x 105 mm)

 

 

Displacement

183 cu. in. (3,000 cc)

 

 

Rated Output

87.4 HP/1800 RPM

 

 

Starting

Electric

 

 

Coolant Capacity

3.57 gal. (13.5 liters)

 

 

Lube Oil Capacity

3.96 gal. (15.0 liters)

 

 

Fuel Type

#2 Diesel Fuel

 

 

Fuel Tank Capacity

103 gal. (390 liters)

 

 

Fuel Consumption

4.1 gal. (15.4 L)/hr at full load

 

3.1 gal. (11.9 L)/hr at 3/4 load

 

 

2.1 gal. (8.10 L)/hr at 1/2 load

 

 

1.3 gal. (4.80 L)/hr at 1/4 load

 

 

 

 

 

 

Battery

12V 72Ah x 1

 

page 12 — DCA70USI3can 60 hz Generator • operation and parts manual — rev. #1 (09/24/13)