Multiquip EGC1000C warranty Cooling System, Fuel System, Lubrication System, Derating 60Hz

Models: EGC1000C

1 4
Download 4 pages 9.97 Kb
Page 3
Image 3
Cooling System

1000 kW Containerized Diesel Generator Set

Cooling System

 

 

Exhaust Manifold Type

Dry

Radiator Design

Standard Horizontal

Coolant Capacity - Engine Only

37 gal. (140 L)

Water Pump Design/Type

Belt Driven, Centrifugal

Coolant Flow

100 gal/min (378 L/min)

Heat Rejection to Coolant (Standby)

40600 Btu/min (715 kW)

Thermostat Range

180-200°F (82-93°C)

Fuel System

Recommended Fuel

 

ASTM-D975/No.1 & No.2-D

Filter Micron Size

 

 

2

Total Fuel Flow

 

150 gal./hr. (568 L/Hr.)

 

 

 

 

 

 

Fuel Consumption

 

 

Diesel at % of Load

 

gal/hr

 

L/hr

25%

 

19.3

 

7.3

50%

 

36.0

 

136

75%

 

52.6

 

199

100%

 

69.3

 

262

Lubrication System

Type

Full Pressure

 

 

Oil Filters

4 Spin-on Full Flow

 

 

Oil Pressure at Rated Speed

45-56 psi (310-386 kPa)

Oil Capacity with Filters

35 gal (132 L)

 

 

Derating (60Hz)

 

Altitude

Ambient

The engine power available up to 4958 ft.

Temperature

 

at temperatures up to 104oF and up to

Above 4958 ft.

 

4433 ft. at 122°F at standby rating, without

derate at 3.4%

Above 122°F,

derating. For operation at higher altitudes

per 1000 ft. up to

and ambient temperatures, the power

9843 ft. Derate

derate an

additional

should be derated according to the

an additional 9%

15% per 18°F

following factors:

per 1000 ft.

 

 

above 9843 ft.

 

DGC2020 Digital Genset Controller

Digital Controller Features

Local and Remote Generator Control

Automatic and manual starting and stopping

Engine and Generator Protection

Programmable Analog Engine Senders

ECU Communications via SAE J1939

16 Programmable Contact Inputs

Programmable Logic

Automatic Transfer Switch Control (Mains Failure)

Integrated RS485 Modbus Connection

Auto Synchronizing

Event recording

Monitoring

Engine RPM

Engine run time

Generator voltage

Generator current

Generator frequency

Oil pressure

Battery voltage

Fuel level measurements

Running Hour Meter

Coolant temperature

Generator under/over voltage alarm/shutdown

Generator under/over frequency alarm/shutdown

Over Current alarm/shutdown

Warm up and cooling functions

Maintenance timer

EGC1000C Rev 3

Page 3
Image 3