TABLE 7. ENGINE TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Inspect carburetor to see if fuel

Check fuel line

 

is reaching it?

 

 

 

 

 

No Fuel?

Add Fuel

 

 

 

 

Water in fuel tank?

Flush or replace fuel tank.

 

 

 

 

Fuel filter clogged?

Replace fuel filter

 

 

 

 

Stuck carburetor?

Check float mechanism.

Poor starting

 

 

Spark plug is red?

Spark plug is fouled. Check tranistor ignition unit.

 

 

 

 

Spark plug is blue-white?

Insufficient compression, injected air leaking. Carburetor jets are

 

clogged (overflow).

 

 

 

 

 

 

No spark present at tip of spark

Tranistor ignition unit broken, high voltage cord cracked or broken.

 

plug?

Start/Stop switch broken. Replace spark plug if fouled.

 

 

 

 

No oil?

Add oil as required.

 

 

 

 

Oil pressure alarm lamp blinks

Check Automatic shutdown circuit "oil sensor".

 

upon starting?

 

 

 

 

 

 

Engine will not turn over?

Replace cylinder and piston and if necessary axel joint.

 

 

 

 

Cylinder head connecting bolts

Tighten cylinder head connecting bolts.

 

loose?

 

 

 

 

 

Insufficient power output "no

Cylinder head gasket damaged?

Replace cylinder head gasket.

compression"

 

 

Malfunction of valve seat?

Re-seat valves.

 

 

 

 

 

Spark plug is loose?

Replace spark plug.

 

 

 

 

Worn piston rings?

Replace piston rings.

 

 

 

 

Malfunction in air-cleaner

Clean or replace air filter.

 

system, air filter clogged?

 

 

 

 

 

 

Air leaking in from interface

Tighten bolts between carburetor and cylinder head. Replace

Insufficient power output

between carburetor and cylinder

cylinder head gasket.

"compression"

head?

 

 

 

 

 

 

Clean or replace fuel filter.

 

Malfunction in fuel system?

Clean or replace carburetor.

 

 

Check carburetor float.

 

 

 

PAGE 34 — GA-6H/GA-6HA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/02/05)

Page 34
Image 34
Multiquip ga-6h manual GA-6H/GA-6HA -TROUBLESHOOTING Engine, Engine Troubleshooting

ga-6h, GA-6HA specifications

The Multiquip GA-6HA is a versatile and robust generator designed to meet the power needs of a variety of applications, particularly in construction, events, and emergency backup situations. With its compact design and impressive performance capabilities, the GA-6HA is an ideal choice for professionals and contractors who require reliable electrical supply in remote locations or during power outages.

One of the standout features of the GA-6HA is its powerful 6,000-watt output, which provides sufficient power to run multiple tools and equipment simultaneously. This generator is equipped with a Honda GX390 engine, known for its durability and fuel efficiency. The engine operates quietly, making it suitable for use in noise-sensitive environments. Furthermore, the advanced design of the engine ensures minimal emissions, aligning with environmental regulations and promoting cleaner operation.

In terms of technology, the GA-6HA is fitted with a heavy-duty alternator that delivers stable power with a rated output of 120/240 volts. This feature allows users to connect various electrical devices without worry of voltage fluctuations that could damage sensitive equipment. The generator also incorporates a manual reset circuit breaker for added safety, preventing overload conditions.

Durability is a significant characteristic of the GA-6HA, as it is built with a rugged steel frame that can withstand the rigors of outdoor use. The generator's design includes an integrated lift hook for easy transport and positioning on job sites. Additionally, the anti-vibration mounts help to minimize noise and maintain stability during operation.

The GA-6HA features multiple outlets, including 120V 20A duplex receptacles and a 120/240V 30A locking receptacle, providing flexibility for connecting various tools and appliances. An easy-to-read fuel gauge and easy-access control panel contribute to user-friendliness and operational efficiency.

Overall, the Multiquip GA-6HA is designed to be a reliable power solution, effectively combining performance, durability, and portability. Whether for construction sites, outdoor recreational activities, or emergency power needs, this generator stands out for its impressive features and user-centric design.