GA-6H/GA-6HA — RULES FOR SAFE OPERATION

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using generators.

NEVER leave the generators unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

ALWAYS ensure generators are on level ground before use.

DO NOT place hands or fingers inside generators engine compartment when engine is running.

NEVER run engine without air cleaner. Severe engine damage may occur.

NEVER change or adjust the engine speed which has been

set at the factory prior to shipping.

Power Cord Safety

NEVER let power cables or cords lay in water.

NEVER stand in water while AC power from the generators is being transfer to a load.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper power or extension cord has been selected for the job See Table 4.

Grounding Safety

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and local codes before operating generator. Severe injury or death! by electrocution can result from operating an ungrounded generator.

ALWAYS make sure the generators are properly grounded to a suitable earth ground (GROUND ROD). See installation in this manual.

NEVER use gas piping as an electrical ground.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

HighTemperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot! components can cause serious burns.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and replace any broken parts immediately.

ALWAYS replace any worn or damaged warning decals.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and un-authorized personnel.

The electrical voltage required to operate the generators can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Removing the engine oil drain plug while the engine is hot will result in hot oil to gush out of the oil drain plug, therefore causing severescaldingtoanypersonsinthegeneral area of the generator.

GA-6H/GA-6HA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/02/05) — PAGE 9

Page 9
Image 9
Multiquip ga-6h, GA-6HA manual Power Cord Safety

ga-6h, GA-6HA specifications

The Multiquip GA-6HA is a versatile and robust generator designed to meet the power needs of a variety of applications, particularly in construction, events, and emergency backup situations. With its compact design and impressive performance capabilities, the GA-6HA is an ideal choice for professionals and contractors who require reliable electrical supply in remote locations or during power outages.

One of the standout features of the GA-6HA is its powerful 6,000-watt output, which provides sufficient power to run multiple tools and equipment simultaneously. This generator is equipped with a Honda GX390 engine, known for its durability and fuel efficiency. The engine operates quietly, making it suitable for use in noise-sensitive environments. Furthermore, the advanced design of the engine ensures minimal emissions, aligning with environmental regulations and promoting cleaner operation.

In terms of technology, the GA-6HA is fitted with a heavy-duty alternator that delivers stable power with a rated output of 120/240 volts. This feature allows users to connect various electrical devices without worry of voltage fluctuations that could damage sensitive equipment. The generator also incorporates a manual reset circuit breaker for added safety, preventing overload conditions.

Durability is a significant characteristic of the GA-6HA, as it is built with a rugged steel frame that can withstand the rigors of outdoor use. The generator's design includes an integrated lift hook for easy transport and positioning on job sites. Additionally, the anti-vibration mounts help to minimize noise and maintain stability during operation.

The GA-6HA features multiple outlets, including 120V 20A duplex receptacles and a 120/240V 30A locking receptacle, providing flexibility for connecting various tools and appliances. An easy-to-read fuel gauge and easy-access control panel contribute to user-friendliness and operational efficiency.

Overall, the Multiquip GA-6HA is designed to be a reliable power solution, effectively combining performance, durability, and portability. Whether for construction sites, outdoor recreational activities, or emergency power needs, this generator stands out for its impressive features and user-centric design.