Multiquip GA-6HE/GA-6HEA Installation, Outdoor Installation, Mounting, Indoor Installation

Models: GA-6HE GA-6HEA

1 86
Download 86 pages 51.06 Kb
Page 21
Image 21

GA-6HE/GA-6HEA — INSTALLATION

Outdoor Installation

Install the generator/welder in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generators are on secure level ground so that it cannot slide or shift around. Also install the generators in a manner so that the exhaust will not be discharged in the direction of nearby homes.

The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture. Failure to do will result in deterioration of the insulation and will result in short circuits and grounding.

Foreign materials such as dust, sand, lint and abrasive materials have a tendency to cause excessive wear to engine and alternator parts.

CAUTION

Pay close attention to ventilation when operating the generators inside tunnels and caves.The engine exhaust contains noxious elements.

Mounting

The generators should always be mounted on a flat level surface to isolate vibration of the generators when it is running. DO NOT place the generators on slopes, the possibility exists that the generators could slide.

CAUTION

An electric shock is apt to happen when vibrators are used. Pay close attention to handling when operating vibrators and always use rubber boots and gloves to insulate the body from a short circuit.

Indoor Installation

Exhaust gases from gasoline engines are extremely poisonous. Whenever an engine is installed indoors the exhaust fumes must be vented to the outside. The engine should be installed at least two feet from any outside wall. Using an exhaust pipe which is too long or too small can cause excessive back pressure which will cause the engine to heat excessively and possibly burn the valves.

Eliminate the danger of deadly carbon monoxide gas. Remember that exhaust fumes from any gasoline engine are very poisonous if discharged in a closed room, but harmless if allowed to mix with the outside air. If the generators is installed indoors, you must make provisions for venting the engine exhaust to the outside of the building.

Generator Grounding

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground. Always use the ground terminal on the generators to ground the generators. Ground the generators from its ground connector so that the resistance to ground is 500 ohms or less.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

NEC articles 250-64(b) and 250-66 set the following grounding requirements:

1.Use one of the following wire types to connect the generators to earth ground.

a.Copper - 10 AWG (5.3 mm2) or larger.

b.Aluminum - 8 AWG (8.4 mm2) or larger.

2.When grounding the generators (Figure 3) connect the ground cable between the lock washer and the nut on the generators and tighten the nut fully. Connect the other end of the ground cable to earth ground.

3.NEC article 250-52(c) specifies that the earth ground rod should be buried a minimum of 8 ft. into the ground.

GA-6HE/GA-6HEA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #1 (09/30/05) — PAGE 21

Page 21
Image 21
Multiquip manual GA-6HE/GA-6HEA Installation, Outdoor Installation, Mounting, Indoor Installation, Generator Grounding

GA-6HE, GA-6HEA specifications

The Multiquip GA-6HEA and GA-6HE are innovative generators designed to cater to diverse power needs in various applications, including construction sites, outdoor events, and emergency situations. These models are noted for their robust design and advanced technologies, making them reliable choices for users who demand performance and durability.

One of the main features of the GA-6HEA and GA-6HE is their powerful engine. The generator is equipped with a high-performance engine that provides a consistent and reliable power output. This enables users to run multiple tools or equipment simultaneously without experiencing dips in performance. Moreover, the engines are designed to minimize fuel consumption while maximizing output, ensuring that users can operate for extended periods without the need for constant refueling.

Another standout characteristic of the GA-6HEA and GA-6HE is their versatility. These generators come with multiple outlets, allowing the connection of various devices and tools. Whether for powering job site tools, lighting, or other equipment, these generators deliver the necessary power without hassle. The models are also compact enough to transport easily, making them ideal for mobile applications.

In terms of technology, the generators feature advanced noise reduction technologies that enhance user comfort. They operate quietly, making them suitable for use in residential areas or noise-sensitive environments. This focus on reducing operational noise does not compromise their power output, allowing users to maintain efficiency while adhering to local noise regulations.

Additionally, the GA-6HEA and GA-6HE incorporate user-friendly interfaces and controls, simplifying operation. With easy-start mechanisms and intuitive control panels, users can operate the generators without extensive training or experience. Safety features are also a priority, with built-in protections against overloads and low oil levels, ensuring the longevity of the equipment.

To summarize, the Multiquip GA-6HEA and GA-6HE are exceptional generators equipped with powerful engines, versatile outlets, advanced noise reduction technologies, and user-friendly controls. Their robust design, combined with superior operational characteristics, makes them ideal for a wide range of power generation needs, ensuring reliability and efficiency in any situation. These generators stand out as a go-to choice for professionals seeking dependable power solutions.