components (generator)
| 15 |
| 120 |
POWERED by | V 240 |
Honda Engines |
|
OFF | AC VOLTMETER |
VOLTOMETRE CA |
MARCHE ON MARCHE ON
240V
AC CIRCUIT | ARRET | OFF ARRET | OFF |
|
| ||
BREAKER | GFCI CIRCUIT | IDLE |
| OPERATION | START |
| |
(for main) | BREAKER | CONTROL | SWITCH |
| BUTTON | 120V | |
INTERRUPTEUR DE INTERRUPTEUR DE | CONTROL | INTERRUPTEUR | BOUTON DE | ||||
COURANT PRINCIPAL | COURANT | DE RALENTI | DE OPERATION | DEMARRAGE |
|
12
13
14
22
16 17
20
18
19
21
Figure 4. Generator Components (continued)
12.Spark Plug – Provides spark to the ignition system. Set spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch) Clean spark plug once a week.
13.Muffler/Heat Shield – Used to reduce noise and emissions. NEVER touch this heat shield when the generator/welder is in use. Always allow time for engine to cool before servicing.
14.Air Cleaner – Prevents dirt and other debris from entering the fuel system. Remove
15.Fuel Tank Cap – Remove this cap to add unleaded gasoline to the fuel tank. Replenish with clean unleaded gasoline. Make sure cap is tightened securely. DO NOT over fill
16.Choke Lever – Used for starting the engine. Close the choke lever when starting a cold engine or in cold weather conditions. The choke enriches the fuel mixture. Open the choke lever if starting a warm engine or in warm weather conditions
17.Fuel Cock Lever – Turn this lever downward to start (down)the flow of fuel into the carburetor. Turn upward to stop (up) the flow of fuel.
18.Engine Oil Filler Cap – Remove this cap/dipstick when the adding of engine oil is required. See Table 4 for recommended type engine oil.
19.Engine Oil Drain Plug – Remove this drain plug when draining of the oil from the engine crankcase is required. Fill with recommeded type oil as listed in Table 4.
20.Recoil Starter (pull rope) –
21.Fuel Tank – Fuel tank capacity is 5 gallons (19 liters)
22.Fuel Gauge – This gauge is located on top of the fuel tank. Read this gauge to determine when fuel is low.
NOTICE
This HONDA engine is equipped with a low oil shutdown capability. A built in sensor will automatically turn off the engine should the oil level fall below a safe operating condition. Make sure the generators is placed on level ground. Placing the generators on level ground will ensure that the low oil sensor will function properly.
page 18 —