Multiquip GAC6HZ manual operation, Main Circuit Breaker ON, Idle Control Switch OFF

Models: GAC6HZ

1 84
Download 84 pages 6.73 Kb
Page 22
Image 22
Figure 19. Main Circuit Breaker (ON)

operation

Figure 17. Idle Control Switch (OFF)Figure 20. GFCI Circuit Breaker (ON) NOTICE

DO NOT pull the starter rope all the way to the end.

DO NOT release the starter rope after pulling. Allow it to rewind as soon as possible..

7.If the engine has started, slowly return the choke lever (Figure 13) to the OPEN position. If the engine has not started repeat steps 1 through 8.

8.Before the generator is placed into operation, run the engine for 3-5 minutes. Check for abnormal smells, fuel leaks, and noises that would associate with lose components.

9.Place idle control switch (Figure 17) in the OFF (down) position.This will allow the engine speed to run at about 3600 RPM's.

10.Place main circuit breaker (Figure 19) in the ON position.

Figure 19. Main Circuit Breaker (ON)

11.Place GFCI circuit breaker (Figure 20) in the ON position.

Figure 17. Idle Control Switch (OFF)

Figure 21. 120V/GFCI Receptacles NOTICE

Placing the idle control switch in the OFF position (Figure 17) allows the engine to operate at a maximum speed of about 3600 RPM's.

When the idle control switch (Figure 18) is placed in the up position (ON), the generator will run at idle speed (2200 RPM's) until a load is applied, at that time the engine speed will increase to 3600 RPM's as long as a load is being applied.

When the load is not in use, the engine speed will drop back to the idle mode after about 3 seconds.

Figure 20. GFCI Circuit Breaker (ON)

12.Read voltmeter on front panel of generator (Figure 21) and verify that 120 VAC is displayed. Using an external voltmeter as shown in Figure 21, verify that 120 VAC is present at the 120V twist-lock and GFCI duplex receptacles. .

Figure 21. 120V/GFCI Receptacles

Figure 18. Idle Control switch (ON)

page 22 — GAC-6HZ 60 hz gENERATOR• operation and parts manual — rev. #1 (03/31/10)

Page 22
Image 22
Multiquip GAC6HZ manual operation, Main Circuit Breaker ON, Idle Control Switch OFF, GFCI Circuit Breaker ON