GDP-5H — RULES FOR SAFE OPERATION

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using generator.

NEVER leave the generator unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

ALWAYS ensure generator is on level ground before use.

DO NOT place hands or fingers inside generator engine compartment when engine is running.

NEVER run engine without air cleaner. Severe engine damage may occur.

NEVER change or adjust the engine speed which has been set at the factory prior to shipping.

Power Cord Safety

NEVER let power cables or cords lay in water.

NEVER stand in water while AC power from the generator is being transfer to a load.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper power or extension cord has been selected for the job See Tables 4 and 5.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

HighTemperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot! components can cause serious burns.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and replace any broken parts immediately.

ALWAYS replace any worn or damaged warning decals.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and un-authorized personnel.

The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Grounding Safety

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and local codes before operating generator. Severe injury or death! by electrocution can result from operating an ungrounded generator.

ALWAYS make sure generator is properly grounded to a suitable earth ground (GROUND ROD). See installation section in this manual.

NEVER use gas piping as an electrical ground.

Removing the engine oil drain plug while the engine is hot will result in hot oil to gush out of the oil drain plug, therefore causing severe scalding to any persons in the general area of the generator.

GDP-5H A.C. GENERATOR — PARTS & OPERATION MANUAL — REV. #2 (10/05/05) — PAGE 9

Page 9
Image 9
Multiquip manual GDP-5H Rules for Safe Operation

GDP-5H specifications

The Multiquip GDP-5H is a robust and versatile piece of equipment designed for various industrial applications, particularly in construction and heavy-duty operations. As part of Multiquip's lineup, the GDP-5H stands out owing to its exceptional performance, durability, and user-friendly design.

One of its main features is the powerful Honda GX160 engine, which provides reliable performance and ensures efficient operation. The engine is known for its longevity and low maintenance requirements, allowing operators to focus on their tasks without frequent interruptions. Additionally, the GDP-5H has a compact design, making it easy to transport and maneuver in tight job sites.

The GDP-5H comes equipped with a hydraulic pump that delivers high flow rates, allowing for fast and efficient operation. This is particularly advantageous when working with multiple attachments or in demanding environments where time is of the essence. The hydraulic system is engineered for maximum reliability and ease of maintenance, featuring components that are readily accessible.

In terms of versatility, the GDP-5H can be fitted with various attachments, making it suitable for a range of applications, from trenching to lifting and beyond. This adaptability not only enhances productivity but also allows companies to optimize their investment in equipment.

Safety is a priority in the design of the Multiquip GDP-5H. It features operator-friendly controls that are intuitive and easy to understand, minimizing the risk of accidents and enhancing overall operational safety. Additionally, the equipment is designed with protective measures to safeguard both the operator and the machine from potential hazards.

The GDP-5H also emphasizes convenience through its fuel efficiency and reduced emissions, meeting stringent industry standards. This is increasingly important in today's world, where environmental considerations play a critical role in equipment selection.

In summary, the Multiquip GDP-5H is a powerful, adaptable, and user-friendly machine that addresses the needs of various industrial applications. Its combination of a reliable Honda engine, efficient hydraulic system, safety features, and versatility positions it as a valuable asset for any construction or heavy-duty operation. Whether used for site preparation, material handling, or other tasks, the GDP-5H proves to be an essential tool for productivity and efficiency on the job.