MQ-D206H— RULES FOR SAFE OPERATION

NEVER Run engine without air cleaner. Severe engine damage may occur.

ALWAYS read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using pump.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

NEVER leave the pump unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

NEVER pump volatile, explosive, flammable or low flash point fluids.These fluids could ignite or explode.

NEVER operate the pump in an explosive atmosphere.

Before starting the pump, check that the clean-out cover is securely fasten.

ALWAYS ensure pump is on level ground before use.

Become familiar with the components of the pump before operating.

ALWAYS replace any worn or damaged warning decals.

NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance.

NEVER open the priming plug when pump is hot. Hot water inside could be pressurized much like the radiator of an automobile. Allow pump to cool to the touch before loosening plug.

NEVER open the pump housing during operation or start the pump with the clean-out cover removed. The rotating impeller inside the pump can cut or sever objects caught in it.

NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.

ALWAYS fill the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump.

In winter drain water from pump housing to prevent freezing.

High Temperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot components can cause serious burns.

NEVER disconnect any "emergency or safety devices". These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death! Disconnection of any of these devices will void all warranties.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts, or missing decals.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

MQ-D206H DIAPHRAGM PUMP — PARTS MANUAL— REV. #0 (12/15/03) — PAGE 11

Page 11
Image 11
Multiquip MQ- D206H manual MQ-D206H- Rules for Safe Operation, Emergencies

MQ- D206H specifications

The Multiquip MQ-D206H is a cutting-edge, high-performance diesel engine generator designed to provide reliable power for a variety of applications, including construction sites, outdoor events, and emergency power needs. This generator stands out in the market due to its robust design, advanced features, and high efficiency, making it a preferred choice among professionals in various industries.

One of the key features of the MQ-D206H is its powerful and durable 206cc diesel engine. This engine is engineered to deliver consistent power output while maintaining excellent fuel efficiency, allowing users to operate the generator for extended periods without the need for frequent refueling. The MQ-D206H is capable of producing up to 6,000 watts of continuous power, making it suitable for running multiple tools and equipment simultaneously.

The generator is equipped with a large fuel tank that offers extended runtime, ensuring that users can rely on it during long working hours without interruptions. Its compact and portable design, complemented by durable wheels and a sturdy frame, allows for easy transportation and setup in various locations. This portability makes it an ideal choice for both stationary use and on-the-go power requirements.

In terms of technology, the Multiquip MQ-D206H features advanced noise reduction technologies, making it one of the quieter generators in its class. The built-in sound attenuated enclosure significantly reduces operational noise, helping to maintain a quieter environment in residential areas or during outdoor events.

Moreover, the MQ-D206H includes innovative safety features such as low oil shutoff and over-current protection, which help safeguard the engine and connected equipment from damage. The user-friendly control panel offers easy access to essential functions, including voltage selection and circuit breakers, allowing for a straightforward operation.

Construction professionals and event organizers will appreciate the high-quality electrical components within the MQ-D206H, which are designed to deliver clean and stable power, ensuring that sensitive electronic devices are protected from voltage surges.

In summary, the Multiquip MQ-D206H is a reliable and versatile diesel generator that excels in performance, fuel efficiency, and portability. With its advanced features and rugged design, it caters to a wide range of power needs, making it an indispensable tool for both professional and recreational users.