Pre-Setup (Pump)

1.Read safety instructions at the beginning of manual.

2.Place pump as near to water as possible,onafirmflat,levelsurface.

3.Toprimepump,removefillcap(Figure2)andfillpumpcasing with water. If the pump casing is not filled with water before starting, it will not begin pumping.

CAUTION - Pump Casing

Pump casing must be filled with water before using pump. Otherwise pump will not be able to begin pumping.

WARNING - High Pressure

DO NOT open fill cap if pump is hot! Water inside may be under pressure. The possibility exists of scalding, resulting in severe bodily harm.

4.Checkforleaksbetweenpumpandengine.Ifwaterisleaking between the pump and engine housing, the seal inside the pumpmaybewornordamaged.Continued operationofthe pumpisnot recommended.Furtherusageofthe pumpunder theseconditionsmaycauseseverewaterdamagetoengine.

Hoses and Clamps

1.Check that all hoses are securely attached to the pump. Make certain suction hose (Figure 2) does not have any air leakage.Tighten hose clamps and couplings as required.

2.Itisrecommendedthat 2 clampsbeusedwhensecuringthe suction hose to the inlet side (suction) of the pump.

3.Remember suction hoses must be rigid enough not to collapse when the pump is in operation.

4.Check that the discharge hose (Figure 2) is not restricted. Place hose so that it lays as straight as it is possible on the ground. Remove any twists or sharp bends from hose which may block the flow of water.

QP-204HPRE-SETUP (PUMP)

Suction and discharge hoses are

NOTE available from Multiquip. Contact your nearest dealer for more information.

5.The discharge hose is usually a collapsible (thin-walled) hose, however if a thin-walled discharge hose is not avail- able, a rigid suction hose can be substituted in its place.

6.Make sure the suction strainer (Figure 2) is clean and securely attached to the water end of the suction hose. The strainer is designed to protect the pump by preventing large objects from being pulled into the pump.

CAUTION - Strainer

The strainer should be positioned so it will remain completely under water. Running the pump with the strainer above water for long periods can damage the pump.

CAUTION - Flammable Fluids-Chemicals

DO NOT pump flammable fluids, corrosive chemicals or fluids containing toxic substances. These fluids can create potentially dangerous health and environmental hazards. Contact local authorities for assistance.

CAUTION - Mechanical Seal

This pump uses a water-cooled mechanical seal to prevent water from seeping into the engine. The passage of water through the pump casing lubricates the seal and prevents it from overheating. NEVER! operate the pump without water in the casing as this will cause damage to the mechanical seal.

QP-204H CENTRIFUGAL PUMP — OPERATION AND PARTS MANUAL— REV. #3 (06/05/06) — PAGE 17

Page 17
Image 17
Multiquip manual QP-204H PRE-SETUP Pump

QP-204H specifications

The Multiquip QP-204H is a powerful and versatile portable generator designed to meet the needs of various applications, from construction sites to outdoor events. As a part of Multiquip's lineup of reliable power equipment, the QP-204H combines innovation, efficiency, and durability to deliver exceptional performance.

At the heart of the QP-204H is a robust Honda GX160 engine, known for its reliability and fuel efficiency. This 4-stroke, air-cooled engine offers a maximum output of 2,400 watts and a rated output of 2,000 watts, ensuring that users have ample power for their equipment and tools. The generator is also equipped with a large-capacity fuel tank, allowing for longer run times without the need for frequent refueling.

One of the standout features of the QP-204H is its lightweight and compact design, weighing just 60 pounds. This portability makes it easy to transport to different job sites or recreational areas. Additionally, the generator is equipped with a convenient built-in handle, further enhancing its ease of mobility.

The QP-204H incorporates advanced noise-reduction technology, making it one of the quieter options available on the market. With a noise level of just 58 dBA at a distance of 7 meters, it is ideal for outdoor activities where noise restrictions may apply. This feature ensures that users can enjoy power without disturbing the surrounding environment.

Safety is also a priority with the Multiquip QP-204H. The generator includes a low-oil shutdown system that automatically turns off the engine in case of low oil levels, helping prevent damage and ensuring prolonged operation. This attention to detail helps to give users peace of mind while using the equipment.

The QP-204H offers multiple outlet options, including 120V AC, making it compatible with a variety of devices and appliances. This versatility allows users to utilize the generator for various tasks, from powering power tools on job sites to providing backup power during outages.

In conclusion, the Multiquip QP-204H stands out as a compact, reliable, and efficient portable generator. With its Honda engine, low noise levels, safety features, and multi-outlet capabilities, it is a go-to solution for both professionals and outdoor enthusiasts alike. Whether it’s job site power needs or recreational activities, the QP-204H is designed to deliver dependable performance in any situation.