QP-204H — RULES FOR SAFE OPERATION

NEVER run engine without air cleaner. Severe engine damage may occur.

ALWAYS read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using pump.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

NEVER leave the pump unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

NEVER pump volatile, explosive, flammable or low flash point fluids.These fluids could ignite or explode.

NEVER operate the pump in an explosive atmosphere.

Before starting the pump, check that the clean-out cover is securely fasten.

ALWAYS ensure pump is on level ground before use.

Become familiar with the components of the pump before operating.

ALWAYS replace any worn or damaged warning decals.

NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance.

NEVER open the priming plug when pump is hot. Hot water inside could be pressurized much like the radiator of an automobile. Allow pump to cool to the touch before loosening plug. The possibility exists of scalding, resulting in severe bodily harm.

NEVER open the pump housing during operation or start the pump with the clean-out cover removed. The rotating impeller inside the pump can cut or sever objects caught in it.

NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.

ALWAYS fill the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump.

In winter drain water from pump housing to prevent freezing.

Maintenance Safety:

NEVER lubricate components or attempt service on a running machine.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

Dispose of hazardous waste properly. Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

TRANSPORTING

ALWAYS shutdown engine before transporting.

Tighten fuel tank cap securely and close fuel cock to prevent fuel from spilling.

Drain fuel when transporting pump over long distances or bad roads.

ALWAYS tie down the pump during transportation by securing the pump's guard frame with rope.

EMERGENCIES

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in case of an emergency.

NEVER disconnect any "emergency or safety devices". These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death! Disconnection of any of these devices will void all warranties.

QP-204H CENTRIFUGAL PUMP — OPERATION AND PARTS MANUAL— REV. #3 (06/05/06) — PAGE 9

Page 9
Image 9
Multiquip manual QP-204H Rules for Safe Operation, Maintenance Safety

QP-204H specifications

The Multiquip QP-204H is a powerful and versatile portable generator designed to meet the needs of various applications, from construction sites to outdoor events. As a part of Multiquip's lineup of reliable power equipment, the QP-204H combines innovation, efficiency, and durability to deliver exceptional performance.

At the heart of the QP-204H is a robust Honda GX160 engine, known for its reliability and fuel efficiency. This 4-stroke, air-cooled engine offers a maximum output of 2,400 watts and a rated output of 2,000 watts, ensuring that users have ample power for their equipment and tools. The generator is also equipped with a large-capacity fuel tank, allowing for longer run times without the need for frequent refueling.

One of the standout features of the QP-204H is its lightweight and compact design, weighing just 60 pounds. This portability makes it easy to transport to different job sites or recreational areas. Additionally, the generator is equipped with a convenient built-in handle, further enhancing its ease of mobility.

The QP-204H incorporates advanced noise-reduction technology, making it one of the quieter options available on the market. With a noise level of just 58 dBA at a distance of 7 meters, it is ideal for outdoor activities where noise restrictions may apply. This feature ensures that users can enjoy power without disturbing the surrounding environment.

Safety is also a priority with the Multiquip QP-204H. The generator includes a low-oil shutdown system that automatically turns off the engine in case of low oil levels, helping prevent damage and ensuring prolonged operation. This attention to detail helps to give users peace of mind while using the equipment.

The QP-204H offers multiple outlet options, including 120V AC, making it compatible with a variety of devices and appliances. This versatility allows users to utilize the generator for various tasks, from powering power tools on job sites to providing backup power during outages.

In conclusion, the Multiquip QP-204H stands out as a compact, reliable, and efficient portable generator. With its Honda engine, low noise levels, safety features, and multi-outlet capabilities, it is a go-to solution for both professionals and outdoor enthusiasts alike. Whether it’s job site power needs or recreational activities, the QP-204H is designed to deliver dependable performance in any situation.