Table 8. Pump Troubleshooting

 

 

TROUBLESHOOTING

 

 

 

 

Table 8. Pump Troubleshooting

 

 

 

Symptom

Possible Cause

Solution

 

 

 

 

Not enough priming water in the housing?

Add water.

 

 

 

 

Engine speed too low?

Increase throttle.

 

 

 

 

Strainner plugged?

Clean strainer.

 

 

 

 

Suction hose damaged?

Replace or repair hose, and clamps

 

 

 

 

Air leak at suction port?

Check that fi ttings are tight and properly

Pump does not take on

sealed.

 

 

 

Pump is located too high above water line?

Move pump closer to water.

water.

 

Debris collecting in pump housing?

Clean pump housing.

 

 

 

 

Too much distance between impeller and

Adjust clearance by adding shims or replace

 

volute?-

impeller. Min. .006"" - Max. .020""

 

 

 

 

Water leaking out weep hole between pump

Check condition of mechanical seal and

 

gaskets, between pump end and engine

 

and engine?

 

housing.

 

 

 

Engine speed too low?

Increase throttle speed.

 

 

 

Pump takes in water,

Suction strainer partially plugged?

Clean strainer.

little or no discharge.

 

 

Impeller/Volute worn?

Adjust clearance by adding shims or replace

 

 

impeller/volute

 

 

 

 

 

Suction hose leaks at

Fittings/clamps are not sealed properly?

Tighten, replace or add clamp. (Keep extra

seals on pump)

inlet.

 

 

 

Hose diameter is too large?

Use smaller diameter hose or replace hose.

 

Discharge does not stay

Pressure too high?

Check pressure, add additional clamp.

on coupling.

Hose kinked or end blocked?

Check hose.

 

Impeller jammed or blocked?

Open pump cover and clean dirt and debris

 

from inside housing.

Impeller does not turn:

 

 

 

 

Adjust clearance by removing shim from

pump is hard to start.

Impeller and volute binding?

behind impeller.

 

 

 

 

 

 

Defective engine?

See Engine Owner's Manual.

 

 

 