QP3TE — PUMP COMPONENTS

Figure 2 shows a typical application using the QP3TE Trash pump. Please note that this pump is intended for the removal of clean water and water containing some debris and solids. Maximum size of solids should not exceed 1.5 inch (38 mm) in diameter. DO NOT set strainer on bottom of water bed. Placing the strainer above the water bed will prevent the pump from drawing in excessive amounts of sand and foreign debris.

Figure 2. QP3TE Pump Application

1.

Pump – The model QP3TE is a 3-inch trash pump used in

 

general dewatering applications. Typical dewatering

 

applications consist of manholes, septic tanks, fast and

 

slow seepage ditch water, silt water, mud water and muck

 

water.

2.

Fill Cap – Prior to operation, the pump casing should be

 

filled with water.Remove this cap to add water to the pump.

 

After the initial prime, a sufficient amount of water will be

 

retained in the casing so that the operator will not need to

 

re-prime later.

 

If the casing is dry or has insufficient water, the pump will

 

have difficulty in priming which could lead to premature

 

mechanical seal wear thus causing damage to the pump.

3.

Discharge Port – Connect a 3-inch discharge hose to this

 

port.

4.

Worm Clamp – Used to secure the hose to the inlet and

 

outlet ports on the pump. Use two clamps to secure the

 

hose on the inlet side of the pump.

5.

Discharge Hose – Connect this flexible rubber hose to

 

the discharge port on the pump. Make sure that the hose

 

lays flat and is not kinked. Use only recommended type

 

discharge hose. Contact Multiquip Parts Department for

 

ordering information.

6. Suction Port – Connect a 3-inch inlet hose to this port. Use two worm clamps to secure the hose.

7. Suction Hose – Connect this flexible rubber hose to the suction port on the pump. Make sure that the hose lays flat and is not kinked. Use only recommended type suction hose. Contact Multiquip Parts Department for ordering information

8. Clean-out Cover Handles – To gain access to the pump's clean-out area, grip both handles, then pull to remove cover. Make sure both locking knobs have been released before attempting to remove clean-out cover.

9. Drain Plug – Remove this plug to drain water from the pump.

10. Clean-out Cover – Remove cover to gain access to the clean-out area.

11. Locking Knobs– Turn both knobs clockwise to secure clean-out cover, turn counterclockwise to release cover.

12. Strainer – Always attach a strainer to bottom side of the suction hose to prevent large objects and debris from entering the pump. Strainer should be positioned so that it will remain completely under water.Running the pump with the strainer above water for long periods can damage pump.

QP3TE TRASH PUMP — OPERATION AND PARTS MANUAL— REV. #4 (11/15/10) — PAGE 13

Page 13
Image 13
Multiquip manual QP3TE Pump Components, General dewatering applications. Typical dewatering

QP3TE specifications

The Multiquip QP3TE is a robust, portable generator designed to meet the demands of construction sites, outdoor events, and various industrial applications. Renowned for its reliability and performance, the QP3TE is engineered to provide a continuous and efficient power supply.

One of the main features of the QP3TE is its powerful engine. It is equipped with a durable, air-cooled, four-stroke engine that delivers a strong output without compromising fuel efficiency. This makes it not only effective but also economical for extended use. It typically has a fuel tank capacity that allows for many hours of continuous operation, ensuring that your power needs are met without frequent refueling.

The QP3TE stands out for its advanced technologies, including a digital inverter system. This technology ensures clean and stable power, making it suitable for sensitive electronics. Whether you’re using it to power construction tools or delicate devices, the inverter technology minimizes the risk of surges or spikes that could cause damage, rendering the QP3TE a versatile choice for both professional and recreational applications.

In addition to its robust power capabilities, the Multiquip QP3TE is designed with user-friendliness in mind. It features an intuitive control panel that allows for easy operation. Users can easily manage power output, monitor fuel levels, and access start and stop functions without any hassle. Comfort is also a priority; the generator is designed with a compact and lightweight form factor, making it easy to transport and set up in various locations.

Durability is another hallmark of the QP3TE. Constructed with high-quality materials, it’s built to withstand harsh working environments and adverse weather conditions. The generator is also equipped with a protective frame that helps absorb shocks and minimize wear and tear, enhancing its longevity.

Moreover, the QP3TE is engineered to comply with stringent emission standards, ensuring that it operates efficiently while minimizing its environmental footprint. This is an essential consideration for contractors and businesses focused on sustainability.

In summary, the Multiquip QP3TE generator combines powerful, efficient operation with user-friendly features and advanced technologies, making it a top-tier choice for a range of applications. Its enduring build quality, coupled with innovative design, ensures reliability and ease of use for professionals and outdoor enthusiasts alike. Whether for construction, events, or emergency backup, the QP3TE stands as a testament to Multiquip's commitment to quality and performance.