NEVER Run engine without air cleaner. Severe engine damage may occur.

ALWAYS read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using pump.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

NEVER leave the pump unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

NEVER pump volatile, explosive, flammable or low flash point fluids.These fluids could ignite or explode.

NEVER operate the pump in an explosive atmosphere.

Before starting the pump, check that the clean-out cover is securely fasten.

ALWAYS ensure pump is on level ground before use.

Become familiar with the components of the pump before operating.

ALWAYS replace any worn or damaged warning decals.

NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance.

NEVER open the priming plug when pump is hot. Hot water inside could be pressurized much like the radiator of an automobile. Allow pump to cool to the touch before loosening plug.

NEVER open the pump housing during operation or start the pump with the clean-out cover removed.The rotating impeller inside the pump can cut or sever objects caught in it.

NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.

ALWAYS fill the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump.

In winter drain water from pump housing to prevent freezing.

RULES FOR SAFE OPERATION

High Temperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot components can cause serious burns.

NEVER disconnect any "emergency or safety devices". These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death! Disconnection of any of these devices will void all warranties.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts, or missing decals.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

QP40TH — PARTS & OPERATION MANUAL — REV. #1 (10/01/02) — PAGE 9

Page 9
Image 9
Multiquip QP40TH operation manual Rules for Safe Operation

QP40TH specifications

The Multiquip QP40TH is a robust and reliable portable generator that stands out in the industry for its powerful performance and innovative features. Designed to cater to various applications, including construction sites, outdoor events, and emergency backup power, this generator delivers an impressive balance of power and portability.

One of the key features of the QP40TH is its 40 kW output capacity, which makes it suitable for a range of applications where high power is necessary. This generator is equipped with a three-phase generator system that ensures efficient energy distribution, enabling multiple tools and equipment to run simultaneously. With a fuel-efficient operation, the QP40TH keeps operational costs down while providing consistent power delivery.

The QP40TH utilizes a high-performance diesel engine that boasts reliability and durability, making it ideal for heavy-duty use. Its industrial-grade engine is designed to withstand the rigors of job sites, ensuring long-lasting performance under challenging conditions. Additionally, the generator features a robust frame and protective enclosure, allowing it to endure harsh environments while keeping internal components secure.

In terms of technology, the Multiquip QP40TH is equipped with advanced digital control systems that enhance user experience. The intuitive control panel provides easy access to essential information such as voltage output, frequency, and hour meter. This ease of monitoring ensures that users can manage their power needs effectively without complications.

Furthermore, the generator is designed with improved noise reduction technologies, enabling quieter operation compared to traditional models. This feature is particularly beneficial for events or locations where noise regulations must be adhered to. The QP40TH also includes a fuel tank that ensures extended run times, minimizing downtime for refueling and keeping projects on schedule.

Safety is a priority with the QP40TH, which is equipped with automatic shut-off features that protect the generator from overloads and low oil levels. These safety mechanisms provide peace of mind for users, safeguarding both the generator and connected equipment.

With its combination of power, efficiency, and reliability, the Multiquip QP40TH is a versatile generator that meets the demands of various applications. Its robust features and state-of-the-art technology make it a go-to choice for professionals in construction, events, and emergency services, ensuring that power needs are met with confidence.