Before Starting

1.Read safety instructions at the beginning of manual.

2.Place pump as near to water as possible,onafirmflat,levelsurface.

3.Toprimepump,removefillcap(Figure2)andfillpumpcasing with water. If the pump casing is not filled with water before starting, it will not begin pumping.

CAUTION :

Pump casing must be filled with water before using pump. Otherwise pump will not be able to begin pumping.

WARNING :

DO NOT open fill cap if pump is hot!Water inside may be under pressure.

QP40TH — PRE-SETUP (PUMP)

Suction and discharge hoses are

NOTE available from Multiquip. Contact your nearest dealer for more information.

5.The discharge hose is usually a collapsible (thin-walled) hose, however if a thin-walled discharge hose is not avail- able, a rigid suction hose can be substituted in its place.

6.Make sure the suction strainer (Figure 2) is clean and securely attached to the water end of the suction hose. The strainer is designed to protect the pump by preventing large objects from being pulled into the pump.

CAUTION :

The strainer should be positioned so it will remain completely under water. Running the pump with the strainer above water for long periods can damage the pump.

4.Checkforleaksbetweenpumpandengine.Ifwaterisleaking between the pump and engine housing, the seal inside the pump may be worn or damaged. Continued operation of the pumpisnot recommended.Furtherusageofthe pumpunder theseconditionsmaycauseseverewaterdamagetoengine.

Hoses and Clamps

1.Check that all hoses are securely attached to the pump. Make certain suction hose (Figure 2) does not have any air leakage.Tighten hose clamps and couplings as required.

2.Itisrecommendedthat 2 clampsbeusedwhensecuringthe suction hose to the inlet side (suction) of the pump.

3.Remember suction hoses must be rigid enough not to collapse when the pump is in operation.

4.Check that the discharge hose (Figure 2) is not restricted. Place hose so that it lays as straight as it is possible on the ground. Remove any twists or sharp bends from hose which may block the flow of water.

CAUTION :

DO NOT pump flammable fluids, corrosive chemicals or fluids containing toxic substances. These fluids can create potentially dangerous health and environmental hazards. Contact local authorities for assistance.

CAUTION :

This pump uses a water-cooled mechanical seal to prevent water from seeping into the engine. The passage of water through the pump casing lubricates the seal and prevents it from overheating. NEVER! operate the pump without water in the casing as this will cause damage to the mechanical seal.

PAGE 16 —QP40TH — PARTS & OPERATION MANUAL — REV. #1 (10/01/02)

Page 16
Image 16
Multiquip operation manual QP40TH PRE-SETUP Pump, Read safety instructions at the beginning of manual

QP40TH specifications

The Multiquip QP40TH is a robust and reliable portable generator that stands out in the industry for its powerful performance and innovative features. Designed to cater to various applications, including construction sites, outdoor events, and emergency backup power, this generator delivers an impressive balance of power and portability.

One of the key features of the QP40TH is its 40 kW output capacity, which makes it suitable for a range of applications where high power is necessary. This generator is equipped with a three-phase generator system that ensures efficient energy distribution, enabling multiple tools and equipment to run simultaneously. With a fuel-efficient operation, the QP40TH keeps operational costs down while providing consistent power delivery.

The QP40TH utilizes a high-performance diesel engine that boasts reliability and durability, making it ideal for heavy-duty use. Its industrial-grade engine is designed to withstand the rigors of job sites, ensuring long-lasting performance under challenging conditions. Additionally, the generator features a robust frame and protective enclosure, allowing it to endure harsh environments while keeping internal components secure.

In terms of technology, the Multiquip QP40TH is equipped with advanced digital control systems that enhance user experience. The intuitive control panel provides easy access to essential information such as voltage output, frequency, and hour meter. This ease of monitoring ensures that users can manage their power needs effectively without complications.

Furthermore, the generator is designed with improved noise reduction technologies, enabling quieter operation compared to traditional models. This feature is particularly beneficial for events or locations where noise regulations must be adhered to. The QP40TH also includes a fuel tank that ensures extended run times, minimizing downtime for refueling and keeping projects on schedule.

Safety is a priority with the QP40TH, which is equipped with automatic shut-off features that protect the generator from overloads and low oil levels. These safety mechanisms provide peace of mind for users, safeguarding both the generator and connected equipment.

With its combination of power, efficiency, and reliability, the Multiquip QP40TH is a versatile generator that meets the demands of various applications. Its robust features and state-of-the-art technology make it a go-to choice for professionals in construction, events, and emergency services, ensuring that power needs are met with confidence.