CAUTION

DO NOT attempt to operate the pump until the Safety, General Information and Inspection sections of this manual have

been read and

thoroughly

understood.

 

This section is intended to assist the operator with the initial start-upof the trash pump. It is extremely important that this section be read carefully before attempting to use the pump in the field.

Starting the Engine

1.Place the engine fuel valve lever (Figure 6) to the "ON" position.

Figure 6. Engine Fuel Valve Lever (ON Position)

2.Move the throttle lever (Figure 7) away from the slow position, about 1/3 of the way toward the fast position.

Figure 7. Throttle Lever (1/3 Start Position)

INITIAL START-UP (ENGINE)

3.Place the choke lever (Figure 8) in the "OPEN " position if starting a cold engine.

Figure 8. Engine Choke Lever (Open)

4.Place the chokelever(Figure 9) in the "CLOSED" position if starting a warm engine or the temperature is warm.

Figure 9. Engine Choke Lever (Closed)

5.Place the engine ON/OFF switch (Figure 10) in the "ON " position.

Figure 10. Engine ON/OFF Switch (ON Position)

OPERATION AND PARTS MANUAL — REV. #1 (10/10/08) PAGE 19

Page 19
Image 19
Multiquip QP4TE manual Initial START-UP Engine