Multiquip SS233 manual Troubleshooting, Symptom

Models: SS233

1 20
Download 20 pages 44.83 Kb
Page 13
Image 13

 

 

 

 

 

 

troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2. Pump Troubleshooting

 

 

 

 

Symptom

Possible Problem

 

Solution

 

 

 

 

 

 

 

 

Check that proper voltage (115 VAC

 

 

 

 

 

 

 

1Ø) is being supplied to the pump.

 

 

 

Incorrect voltage/amps?

 

 

Also check that there is an adequate

 

 

 

 

 

amount of current (amps) to run the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pump. Check power source circuit

 

 

 

 

 

 

 

breaker.

 

Pump Fails To Start

 

Check electrical connections?

 

Inspect power cord.

 

 

Blown fuse or defective circuit

 

Replace fuse or circuit breaker. Check

 

 

 

 

 

 

 

 

cause of blown fuse or tripped circuit

 

 

 

breaker?

 

 

 

 

 

 

 

breaker.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disconnect power cord and check

 

 

 

Impeller locked?

 

 

for clogging and improper impeller

 

 

 

 

 

clearance. Unclog pump. Check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

overload protection device.

 

 

 

Twisted or restricted discharge hose?

 

Lay hose flat un-kinked. Remove clog

 

 

 

 

from hose line.

 

 

 

 

 

 

 

 

 

 

 

 

Clogged pump strainer?

 

 

Clean strainer.

 

 

 

 

 

 

 

 

Use a voltmeter to check voltage

Pump Fails to Deliver Full Output

 

 

 

 

while pump is energized. Voltage must

 

 

 

 

 

 

 

be within ±10%. Check power source

 

 

 

Low voltage?

 

 

(no load and load). If an extension

 

 

 

 

 

 

 

cord is used, make sure it has

 

 

 

 

 

 

 

adequate current-carrying capacity for

 

 

 

 

 

 

 

the required length.

 

 

 

 

 

 

 

 

 

Table 3. Cable Selection (60 Hz, Single Phase Operation)

 

Current in

 

Load in Watts

 

Maximum Allowable Cable Length

 

Amperes

 

115 VAC

#10 Wire

 

#12 Wire

 

#14 Wire

 

#16 Wire

2.5

 

300

1000 ft.

 

600 ft.

 

375 ft.

 

250 ft.

5

 

600

500 ft.

 

300 ft.

 

200 ft.

 

125 ft.

7.5

 

900

350 ft.

 

200 ft.

 

125 ft.

 

100 ft.

10

 

1200

250 ft.

 

150 ft.

 

100 ft.

 

 

15

 

1800

150 ft.

 

100 ft.

 

65 ft.

 

 

20

 

2400

125 ft.

 

75 ft.

 

50 ft.

 

 

CAUTION: Equipment damage can result from low voltage.

 

 

 

 

 

SS233 Submersible Pump • operation and parts manual — rev. #2 (03/22/10) — page 13