WM-70 PLASTER/MORTAR MIXER — ELECTRIC MOTOR
The motor supplied is wired for 115 VAC grounded operation. Make certain that the correct size grounded
Motors can burn out when the line voltage falls 5% below the voltage rating of the motor. Failure to use proper voltage will cause the motor to overheat and actuate the overload switch.
If overload protection should actuate because of improper voltage or any other malfunction, turn the main switch on the motor to the OFF position and correct the problem, press the reset switch button, and turn the main switch to the ON position.
Electric Motor Voltage Switch
1.ALWAYS make certain the motor switch is OFF and the power cord has been disconnected from the power source.
2.Remove the voltage
3.Replace the voltage lock-out bolt.
TABLE 6. RECOMMENDED EXTENSION CORD SIZES
Model | Motor | Voltage | 50 ft. | 75 ft. | 100 ft. | 200 ft. |
(15.24 m) | (22.86 m) | (30.48 m) | (60.96 m) | |||
|
|
|
|
|
|
|
1.5 HP | 115 | No. 12 | No. 10 | No. 8 | No. 6 | |
|
|
|
|
| ||
(Electric) | 230 | No. 14 | No. 12 | No. 12 | No. 8 | |
|
| |||||
|
|
|
|
|
|
|
Important!, when changing the input
NOTE voltage to the motor from 115 to 230 VAC the plug on the motor power cord must also be changed. See Table 4