ELECTRIC MOTOR

For lubrication care and operation of the electric motor, refer to your electric motor instruction booklet furnished with the motor.

Protect the electric motor from dust as much as possible and keep ventilating openings clean.

CAUTION:

DO NOT spray water at any time on the electric motor.

DO NOT operate electric motor in a explosive environment.

The electric motor for this mixer is available in either a 5 HP single-phase or 5 HP 3-phase configuration.The input voltage requirement for these motors is either 230 VAC or 440 VAC only.

ELECTRIC MOTOR CONNECTION

A 12 inch electrical cable (Figure 2) with a pigtail at one end is provided with the electrical motor for hookup to a power source. Table 1. shows the required NEMA connector for the desired motor horsepower rating. In addition, Table 2 also shows the matching NEMA approved connector for the required extension cord.

WM-120P/S — ELECTRIC MOTOR

NOTE

It is strongly recommended that all electrical wiring be done by a licensed electrician. Special attention should be given to the electric switch as well as the over-and-under voltage protection devices as per regulations set forth in the local electrical safety code handbook.

Table 2. Electric Motor Wiring Information

Motor

230 Volt - Single Phase

Horsepower

 

 

NEMA Plug Connector

Mating NEMA

Rating

 

Receptacle Connector

 

 

 

 

 

3 HP

L6-20P P/N 940539

L6-20R P/N 940540

 

 

 

5 HP

L6-30P P/N 940547

L6-30R P/N 940548

 

 

 

Figure 2. Single Phase Electric Motor with 12 inch Pigtail Cable

PAGE 12 — WM120PM/SM— OPERATION AND PARTS MANUAL — REV. #7 (09/15/11)

Page 12
Image 12
Multiquip WM120SM, WM120PM manual WM-120P/S Electric Motor, Electric Motor Connection