* Factory setting is for 30mm type.

4. Screw guide position adjustment

Carry out the screw guide position adjustment according to the length of the screws used. * Factory setting is for 45mm screw length.

5. Feeding screws

Insert the VISROPE into the feeder block until it stops. Push the main body by no less than 30mm, and then pull it back.

When the screw is not fed to the center even after the above step was repeated several times, carry out the guide cover adjustment by referring to 6. Adjustment of guide cover and then retry the screw feeding.

4

Page 5
Image 5
MURO VL71-FLR manual Screw guide position adjustment, Feeding screws