Murphy 45 Series dimensions Description, Specifications, Basic Models, Applications, Dimensions

Models: 45 Series

1 2
Download 2 pages 56.38 Kb
Page 1
Image 1
45 Series Pressure Swichgage instrument

45 Series Pressure Swichgage instrument

Revised 07-06

®

45-96003B

To Disable Magneto, CD and Battery Ignition Systems

Catalog Section 05

 

 

 

 

 

Combination Pressure Swichgage instru- ment and Built-in Electromagnetic Switch

High and Low Contacts Can Disable Engine’s Ignition Due to Critical Pressure

Magnetic Switch Will Not Allow Engine Restart Due to Flywheel Inertia
Semi-Automatic Low Pressure Override Push Button for Engine Startup

Description

The 45 Series pressure Swichgage instrument incorporates a built-in electromagnetic switch to disable an ignition whenever the gage con- tacts operate.

Flywheel inertia cannot restart the engine since the electromagnetic switch will not allow the ignition to operate until manually reset.

Asemi-automatic lockout push button over- rides the low pressure contact for equipment startup. The lockout automatically disengages when pressure is established allowing the low limit contact to be armed for operation should a low pressure condition occur.

Specifications

Dial: White on black, dual scale, psi and kPa standard, 4-1/2 in. (114 mm) diameter.

Case: Die cast aluminum.

Process Connection:

1/4 NPT thru 1000 psi (6.9 MPa) [69 bar]; 1/2 NPT 1500 psi (10 MPa) [103 bar] thru 10,000 psi (138 MPa) [1379 bar].

Overrange: Do not exceed 10% above full range.

Sensing Element: Select from bronze or 316 stain- less steel bourdon tube.

Gage Accuracy: ±2% for first and last quarters of scale; the middle half is ±1%.

Basic Models

45B Series Swichgage instrument

For use with 12-32 VDC battery ignition systems; it includes battery ignition type magnetic switch.

45CD Series Swichgage instrument

For use with (CD) capacitor discharge ignitions; it includes CD ignition type magnetic switch.

45M Series Swichgage instrument

For use with magneto type ignitions; it includes magneto ignition type magnetic switch.

45N Series Swichgage instrument

For specific use with 110 VAC Power Sources; it includes 120 VAC type magnetic switch.

Models are available for conventional magnetos, capacitor discharge (CD) ignitions, 12/32 VDC battery systems, and 120 VAC power sources.

Ranges are available from 30”vac (-101 kPa) [-1.01 bar] thru 10,000 psi (138 MPa) [1379 bar].

Applications

Recommended instrument for most field gath- ering pumps, the 45 Series instantly stops your pump when pressures drop due to line breaks, leaks or when your tank is pumped out. Overpressure shutdown can occur due to clo- sure of valves in the line, or other line restrictions.

Pressure Relief Disc: Located in rear of case.

Contact Ratings:

45B = 12/30 VDC coil; 10 A, 32 VD DC contacts 45CD = CD ignition coil; 10 A contacts

45M = Magneto ign. coil; 10 A contacts45N = 120 VAC coil; 10 A, 120 VAC contactsWire Connections:1/2 NPT conduit and terminal block.Item Weight:

5 lbs 9 oz (2.5 kg) approximately.

Item Dimensions:

10 x 9 x 6 in. (254 x 229 x 152 mm).

Dimensions

8-7/16 in.

(214 mm)

3-3/8 in.

(86 mm)

￿

1/2 NPT ￿ conduit

￿

￿