|
|
|
| 518PH Aallows for SWICHGAGE® and/or |
|
|
|
| N.C. contacts to be wired “Closed Loop” (in |
|
|
|
| series). Any contact open or SWICHGAGE® |
|
|
|
| contact close in the circuit shunt trips the |
|
| R |
| 518PH. Specify 12 or 24 VDC. Contacts 10 |
G | NC | SW1 | SW2 B | amps 24V. 14 amp fuse. |
|
|
|
| 518APH Allows for SWICHGAGE® and/or |
|
|
|
| N.C. contacts to be wired “Closed Loop” (in |
|
|
|
| series). Any contact open or SWICHGAGE® |
|
|
|
| contact close in the circuit shunt trips the |
|
|
|
| 518APH. Specify 12 or 24 VDC. Contacts 10 |
|
|
|
| amps 24V. 14 amp fuse. |
|
| R |
|
|
GNO | NC | SW1 SW2 B | 518E Same as 518APH but recommended | |
|
|
|
| for high vibration application where nuisance |
|
|
|
| shutdowns typically occur due to higher than |
|
|
|
| normal vibrations (ie. wood chippers) 12 Volt |
|
|
|
| only. |
520APH Same as 518APH except with 30 |
|
| |
second time delay before trip on one SWICH- |
|
| |
GAGE® contact input but immediate trip on the |
|
| |
second SWICHGAGE® contact input. Typical |
| TD | |
use is for immediate stop of engine from oil |
| R | |
pressure or coolant temperature, but delayed | GNO NC | SW1 SW2 B | |
shutdown from alignment switches on center | |||
|
| ||
pivot irrigation system. Specify 12 or 24 VDC |
|
| |
and length of time delay. Time delays are |
| * | |
available from 5 to 120 seconds. Contacts 10 amps |
| ||
24 V. 14 amp fuse. |
|
|
|
|
|
|
|
|
|
|
|
|
|
760A/760AF/761APH Use for distribu- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
tor ignition or diesel. Time delay lockout of |
|
|
|
|
|
|
|
|
|
|
SWICHGAGE® contacts on |
|
|
|
|
|
| TD |
|
| |
|
|
|
|
|
|
|
|
|
| |
tomer wired for delayed or immediate trip on |
|
|
|
|
|
|
|
|
|
|
shutdown. Breaks and makes circuits when |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
tripped. 760A resets automatically when the |
|
|
|
|
|
|
|
|
|
|
| G NO NC |
| S B | |||||||
shutdown signal is removed or power is |
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
removed. 761APH has manual reset. 760AF is |
|
|
|
|
|
|
|
|
|
|
760A with inline fuse. Must specify 12 or 24 |
|
|
|
|
| * |
| |||
VDC, and length of time delay. Optional time delays: 15, 30 |
| |||||||||
|
|
|
|
|
(standard) or 60 seconds. Contacts 10 amps 24 V. 14 amp fuse. Models 760A and 761APH carry the CE mark.
NOTE : The 760A cannot be adequately protected by a circuit breaker in a dead short condition with a battery as the power source. The circuit breaker will take a finite amount of time to react, during which time the circuit board of the 760A will be dam- aged beyond repair. Fuses are the optimal method for protecting the 760A.
|
|
| 822PH Used in Murphy |
|
|
| master disconnect. 24 VAC coil energizes |
|
|
| when SWICHGAGE® contact closes to |
|
|
| ground; breaks and makes circuit when |
|
|
| tripped. Manual reset. |
NO | NC | C | SW |
M4264 Series Detects loss of |
|
|
|
|
|
magneto/CD ignition output and transfers con- |
|
|
|
|
|
tacts for customer use. Contacts 10 amps; 48 |
|
|
|
|
|
VAC/VDC. | Sensing |
|
|
| |
M42641CD transfers SPDT dry contacts when |
|
|
| ||
Circuit |
|
|
|
| |
tripped. |
|
|
|
|
|
BY | IGN | NO | NC | IGN | C |
G | NC | SW | C |
521PH Use with N.C. SWICHGAGE® or switches to ground magneto or CD ignition when tripped. Trip coil energized to run, de- energized to shutdown when N.C.
contacts open. Specify 12 or 24* VDC. Contacts 10 amps 24 V.
G | NO | NC | S | B |
R129A A SPDT relay with 10 amp dry contacts. Specify 12 or 24 VDC. Contacts 10 amps 24 VDC. 14 amp fuse.
6 | 1 | 2 | 3 | 4 | 5 |
MS2111 Replaces 221PH w/72 ohm coil. Used with
ETS30S All
* Complies with EMC Council directive 89/336/EEC regarding electromagnetic compatibility.
78793B page 3 of 4