Operating Instructions

Before operating the battery charger, ensure that the charger is assembled and installed as per the installation instructions.

WARNING: DANGER OF INJURY OR DEATH

Before connection, disconnection or handling of Guardian battery charger, be sure AC power supplies are off.

NOTE: Connection to or disconnection from live wiring can also cause damage to internal components.

Terminal Connection Information

Output:

To battery

 

CAUTION: Observe correct polarity

Input:

AC supply

 

CAUTION: Observe correct voltage as stated on unit.

Alarm Indication

Over voltage, under voltage and charge fail

Boost:

Boost initiate – Linking these two connectors will force the charger into a

 

single boost cycle of operation. Once the charger has completed a single

 

boost cycle the charger returns to its normal mode of operation.

 

Stripped wire is introduced just before the clamping unit.

 

The clamp spring is pressed down and wire is introduced into the

 

clamping unit immediately.

 

The clamp spring is released – the conductor is automatically clamped.

NOTE: All connections, including AC input and DC output are made via spring- clamp connections as outlined above.