OPERATION

BEFORE STARTING THE ENGINE

CHECK ENGINE OIL LEVEL

The engine in your tractor has been shipped, from the factory, already filled with summer weight oil.

Check engine oil with tractor on level ground.

Remove oil fill cap/dipstick and wipe clean, reinsert the dipstick and screw cap tight, wait for a few seconds, remove and read oil level. If necessary, add oil until “FULL” mark on dipstick is reached. Do not overfill.

For cold weather operation you should change oil for easier starting (See “OIL VISCOSITY CHART” in the Maintenance section of this manual).

To change engine oil, see the Maintenance section in this manual.

ADD GASOLINE

Fill fuel tank to bottom of filler neck. Do not overfill. Use fresh, clean, regular unleaded gasoline with a minimum of 87 octane. (Use of leaded gasoline will increase carbon and lead oxide deposits and reduce valve life). Do not mix oil with gasoline. Purchase fuel in quantities that can be used within 30 days to assure fuel freshness.

CAUTION: Wipe off any spilled oil or fuel. Do not store, spill or use gasoline near an open flame.

IMPORTANT: WHEN OPERATING IN TEMPERATURES BELOW32°F(0°C), USE FRESH, CLEAN WINTER GRADE GASOLINE TO HELP INSURE GOOD COLD WEATHER STARTING.

CAUTION: Alcohol blended fuels (called gasohol or using ethanol or methanol) can at- tract moisture which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. Drain the gas tank, start the engine and let it run until the fuel lines and carburetor are empty. Use fresh fuel next season. See Storage Instructions for additional information. Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur.

TO START ENGINE (See Fig. 5)

When starting the engine for the first time or if the engine has run out of fuel, it will take extra cranking time to move fuel from the tank to the engine.

Sit on seat in operating position, depress clutch/brake pedal and set parking brake.

Place gear shift lever in neutral (N) position.

Move attachment clutch to “DISENGAGED” position.

Move throttle control to choke () position.

NOTE: Before starting, read the warm and cold starting procedures below.

Insert key into ignition and turn key clockwise to “START” position and release key as soon as engine starts. Do not run starter continuously for more than fifteen seconds per minute. If the engine does not start after several attempts, move throttle control to fast position, wait a few minutes and try again. If engine still does not start, move the throttle control back to the choke ( ) position and retry.

WARM WEATHER STARTING (50° F and above)

When engine starts, move the throttle control to the fast position.

The attachments and ground drive can now be used. If the engine does not accept the load, restart the engine and allow it to warm up for one minute using the choke as described above.

COLD WEATHER STARTING ( 50° F and below)

When engine starts, allow engine to run with the throttle control in the choke () position until the engine runs roughly, then move throttle control to fast position. This may require an engine warm-up period from several seconds to several minutes, depending on the tem- perature.

The attachments can also be used during the engine warm-up period.

NOTE: If at a high altitude (above 3000 feet) or in cold temperatures (below 32 F) the carburetor fuel mixture may need to be adjusted for best engine performance. See “TO ADJUST CARBURETOR” in the Service and Adjustments section of this manual.

13

Page 13
Image 13
Murray 96017000500 manual Before Starting the Engine, Check Engine OIL Level, ADD Gasoline, To Start Engine See Fig

96017000500 specifications

Murray 96017000500 represents a cutting-edge technological solution in the realm of industrial generators, designed to cater to diverse power requirements across various sectors. This generator is engineered for reliability, efficiency, and versatility, making it an ideal choice for businesses that necessitate uninterrupted power supply.

One of the standout features of the Murray 96017000500 is its robust power output. With a capacity that easily meets the demands of both small and medium-sized enterprises, this generator ensures that operations can continue smoothly, even during electrical outages. The design is focused on delivering a steady 120/240V output, accommodating a range of equipment and tools.

The generator incorporates advanced engineering that prioritizes fuel efficiency. It operates on a gas-fueled engine which not only enhances performance but also reduces emissions compared to traditional diesel generators. This aspect aligns with the growing global emphasis on sustainable and environmentally friendly practices in business operations.

Durability is another hallmark of the Murray 96017000500. Built with high-quality materials and superior craftsmanship, it is designed to withstand harsh operational conditions. This resilience ensures that the generator can function consistently over extended periods, minimizing downtime and maintenance costs for businesses.

Ease of use is an essential characteristic of this generator. It features an intuitive control panel that allows operators to monitor performance and make adjustments with minimal effort. Quick-connect ports facilitate straightforward setup and integration into existing power systems, making it accessible even for those with limited technical expertise.

Safety features are integrated throughout the design, with overload protection and automatic shut-off mechanisms in place to prevent damage during power surges. These safety measures underscore Murray's commitment to providing products that are not only high-performing but also secure for users.

In terms of portability, the Murray 96017000500 is designed with mobility in mind. Its compact dimensions and lightweight construction allow for easy transportation and installation at various job sites, making it a practical choice for contractors and tradespeople on the move.

In summary, the Murray 96017000500 is a powerful, efficient, and durable generator that meets the demanding needs of contemporary businesses. With its advanced fuel system, user-friendly interface, and built-in safety features, it represents an ideal investment for those looking to ensure a reliable power supply in any situation.