![](/images/new-backgrounds/1199067/19906729x1.webp)
unknown, check the date printed on the bobbin and replace if older than three (3) years (see
7)IMPORTANT! Bobbin (yellow) must be installed into the HOUSING (**see figure 10), white side up, aligning the slots on the bobbin with the ridges inside the threaded housing. The bobbin will slide in easily if installed correctly.
8)Install cap by screwing clockwise until it meets the housing shoulder.
9)Check the new cylinder/bayonet assembly to ensure the
Figure 11 |
|
Solid | Pierced |
Cylinder | Cylinder |
Top | Top |
Attached | Broken |
Sensor | Sensor |
Ring | Ring |
Caution: Do not use the cylinder/bayonet assembly if either the
IMPORTANT: You will damage the sensor ring if bobbin and cap are not installed first.
10)Push, and hold, the lever into the inflator housing. The
WARNING: PFD WILL ONLY INFLATE IF CYLINDER IS TURNED TO A FULL STOP.
11)Examine the service indicator (Fig. 10) and ensure it is GREEN. If the service indicator is red, the mechanism has been fired or is incorrectly fitted and the inflator requires service. See
NOTE: The service indicator must be green before proceeding.
Inflatable PFD Owner’s Manual | 12 |