MAINTENANCE INSTRUCTIONS for leak tests p. 14). It should inflate quick and easily.

·Learn how it works by:

Activating the CO2 inflation system

Re-arming the CO2 inflation system

Using the oral inflator tube

To check the manual inflation system (with CO2 cylinder/bayonet assembly removed); determine that the CO2 cylinder piercing pin moves freely when pushing up on the lever arm by pushing down on the pins and releasing the pins followed by the lever arm (for MD3081 and MD3082 see Fig. 9 and for MD3083 and MD3084 see Fig. 12). Repeat this several times to check the manual inflation system.

MODELS MD3083 and MD3084

The U.S.Coast Guard recommends that you purchase two automatic re-arming kits (MA7202). One kit is to be used immediately in testing the automatic inflation system (see HOW DO YOU TEST YOUR PFD USING THE AUTOMATIC INFLATOR?, p. 18) and the other to carry on board as a spare.

The U.S. Coast Guard recommends you test the automatic inflation system in the water at the beginning of each boating season. By doing this, you demonstrate that the automatic inflation system is still working properly and reduce the likelihood of premature inflation and its associated dangers.

HOW DO YOU TEST YOUR PFD USING THE AUTOMATIC INFLATOR? (MD3083 and MD3084)

1)To test your Inflatable PFD, you will need your fully armed Inflatable PFD, and re-arming kit (MA7202) approved for your Inflatable PFD

2)Put on the Inflatable PFD.

3)Get into shallow water, just deep enough that you can stand with your head above the surface. Once the inflator is underwater the Inflatable PFD should fully inflate automatically within 10 seconds.

4)See if the Inflatable PFD will float you on your back or just slightly back of vertical. In a relaxed floating position, verify that your mouth

Inflatable PFD Owner’s Manual

18

Page 21
Image 21
Mustang Survival MD3082, MD3081 manual Models MD3083 and MD3084, Put on the Inflatable PFD