The left lobe (as worn) of the MD3091 LP contains the oral inflator tube
To become more familiar with the LP components:
1.Open both zippers completely, and place the LP on a smooth, flat surface with the inflator facing the user.
2.Ensure the oral inflator dust cap is in the stowed position.
3.Ensure the status pin and the CO2 cylinder are intact, and the lever is in the up and ready position (Figure 6).
4.If the cylinder is not intact, and/or if the status pin is missing or broken,
5.Repack the LP – see Repacking.
Prior to Use
Visually inspect the LP prior to use to:
FIGURE 5
C A
B
FIGURE 6
CO2 Cylinder
Inator Mechanism
Status Pin
Ination Lanyard
Beaded Manual
Ination Handle
FIGURE 7
Piercing Pin Status Pin
Inflation Lever
•ensure the LP is properly armed
•ensure the LP is free of rips, tears, or holes and all seams are securely sewn
•ensure the fabric, straps, and hardware are free from any defects
READINESS CHECKLIST (MD3196 & MD3091)
When all applicable boxes are checked, the LP is ready for use: FF Beaded manual inflation handle is fastened.
FF No rips, tears, or holes, and all seams securely sewn. FF Fabric, straps, and hardware free from defects.
FF All zippers, Velcro™, and chest buckle securely fastened. FF MD3196 only: Status indicator is green.
FF MD3196 only: Inflator expiry date has not passed.
FF MD3091 only: Status pin and cylinder intact, and manual inflation lever in the up and ready position.
NOTE: If there are any concerns about the readiness of the MD3196 or MD3091, contact the Mustang Survival dealer.